  1. Thanks for doing the video, you do it so much better than I, and much faster . I use a 30 x 42 more often than anything else other than 24x36, sometimes 36x48 also, my clients hate that and want me to cut the plan in half, which I will not do. A smaller scale might work but gets too hard to read, Heck they want me to increase the text size as it is. They are all getting old. like me
  2. You can also hit the "x" key while dragging a corner. Same with text
  3. Scott made a video back then but it would still apply today if he still has it.
  4. Scott, joe and I have been doing it since 2005. just add to your existing layout template
  5. Hey Scott, do you still have your marvelous waterfall video for Kevin.
  6. In your layout you can create a new layout on page 0 and the, size you need ,and put it on a specified layer so next time all you need to do is change layers to get the new layout.
  7. Yes, I'm always fixing those slab room labels, It takes time to do it especially if you have lots of interior footings, lots of rooms to fix, so I set the interior room footings as no definition
  8. Haven't seen that and I use Chief x10 every day, not sure why that would screw up for you,
  9. Make sure "To scale" is checked in the print DBX. Also make sure you sent it at 1/4" scale to the layout.
  10. looks like no sun or it's on the other side of the house putting the front in shadow, try clicking "Sun follows camera" in the sun DBX. Shadows are now controled in each camera's DBX
  11. It works with my e7100i and connected to my ipad.
  12. That's what I love about NVidia, they always keep up.
  13. I have seen this many times and its always an errant attic wall, Scott is correct.
  14. If you upgrade to X10 without bringing your toolbars forward, it will show automatically, but if you do upgrade using your toolbars forward, then you must find it..
  15. This is what I get using framing deminsion defaults. I'm really not familiar with mm so maybe someone else can look at it.
  16. Around here if you have a 2 story a lot of the 1st floor walls will be bearing for the floor joists.. I will need sometimes to change the headers manually with those. depending on the loads
  17. I gave mine to someone here only to find he received an empty envelope with the dongle missing.
  18. post the plan, it seems like you might have the door or wall not configured correctly.
  19. Can you try to use the auto storypole dims and do you have your dims setup to locate framing?