Posts
8632 -
Joined
-
Last visited
Content Type
Profiles
Forums
Gallery
Everything posted by DRAWZILLA
-
Roof lines are too basic for a custom home. When the roof lines are basic then the inside will also be basic. It would take some thought time to get it smoking hot. You can do a lot by changing the roof lines vertically. Good luck
-
Yes, they are macro's that come with the program. Just put them in the room label defaults
-
That's why I have floor and ceiling heights in my room labels, you can see what happened right away.
-
Whatever Happened To The Full Masonry Fireplace And Chimney?
DRAWZILLA replied to Electromen's topic in General Q & A
I think he is talking about the metal inserts, you just need to slide it forward and place a pass-through, for the opening. -
Very interesting. Thanks
-
Here in the L.A. area it nothing but tract homes with a few customs, so it works well for me.
-
Larry has dual Zeon's, it would be interesting to see the difference.
-
My Sam / Template plan is about 20+ pages and has everything I might need with any given job on it. It's a lot easier to delete, than create things. With the auto sheet index and auto section/ elevation pages, I can delete a lot and it's still good to go.
-
I always use an existing plan, and a new plan also, A lot of times I will get a call for another job on the same model or a second job on the same model. This has happened to me at least a 100 times in the past. Like those jobs , the existing plan already done.
-
If one wall is set to "no room def., you can do it.
-
Just put the existing walls on their own layer and uncheck (Mat) in the layer's column. A lot of times you are patching existing walls , so include any walls you think you might patch. I use new and existing walls but don't worry about the materials list. Once it's set up correctly in your template plan, it will work smoothly but its a lot of work to set up. I use a cad mask for any demo work, it doesn't mess with the model and when you remove a wall, the cad mask shows up automatically. Search cad mask here.
-
Yes I remember, if you do your 3d prior to blocking it will be good, but really why after 10+ years, can't Chief fix that. We used to ask to show blocked framing for many years, I guess we gave up and forgot. I guess that's why Chief recommends to frame last. I actually frame very early on. I actually use p-solids for those. Boy the chargers stink this year, maybe it's on purpose, so the league will grant the move. we do need someone, why are we getting 2 teams, I don't get it. New England ,Wow, if you get them, good deal, but I think if they are willing to move ,LA should have them.
- 24 replies
-
- beams
- ceiling plane
-
(and 2 more)
Tagged with:
-
they stay if you block them together before re-building.
- 24 replies
-
- beams
- ceiling plane
-
(and 2 more)
Tagged with:
-
Joe's macro's are great, they have saved me lots of time drawing.
-
Wall lines showing through exterior in elevation view.
DRAWZILLA replied to HaywardVT's topic in General Q & A
You can see in the picture that a drywall layer is going thru the outside wall, just use the "edit wall layer intersections" tool to bring it back to where it should be. -
Someone isn't enforcing it, I guess.
-
I don't think it looks like a spiral stair to me. I pretty sure Scott's post would apply.
-
Every new release has given me new tools to save time, and for me that's what it's all about. I always upgrade and Chief gets me out the door sooner every time.
-
The reason the storage room doesn't work is that those 2 walls are probably set as attic walls which have no room def. Just uncheck no room def. and it will convert to a room.
-
Yes, use a sill without an apron
-
I have to use it on sections for mono slab foundation flubs
-
Where is Scotts waterfall video when you need it?