  1. I actually don't remember where I got it but it was a while back
  2. I use X12, let me see if I have it in X11 yes here it is fireplace wall vent.calibz
  3. here is one fireplace wall vent.calibz
  4. most cities and county's around here are 2019 codes including 2019 energy and California Green codes. I downloaded my free copies.
  5. It might be in the code but I haven't seen it enforced around here. Gee someone might fall out that window, very dangerous. I don't think my head would fit.
  6. Sorry joe , I read it and deleted it, but it was listed with the download.
  7. Joe the list was with the download as a separate item
  8. the plan checkers probably want the plans to be inline with the energy calcs.. North, South etc.
  9. no, you need to place the item in the plan, then change the cad block associated with that electric symbol to add existing. then change the label to what you want it to say..Add the changed item to your lib. for future use.
  10. Good luck finding someone with all those quality's.
  11. Around here, I have done over 4000 additions over 45+ years, and at least for 30 of those years I have needed all existing interior and exterior walls to be shown. I deal with about 50 cities so they vary in the amount of detail needed. A lot of the time we need to brace existing walls for earthquake. also we must show existing for all the energy requirements also needed on every job.. Sounds like fun doesn't it?
  12. It's not?? look at this terrain DBX in X11
  13. also make sure your room divider wall is not checked as invisible
  14. yes, your grade setting in the terrain DBX should be a minus number (-4) if that's what you want it to be.
  15. If you call it a balcony, it will give you a floor system just like a room
  16. Chief just doesn't do that, you cannot add a skylight to the window sched, it would be good if you could though.
  17. It might have been a wi-fi thing, I would just shut down and restart and see if its there.
  18. to show rebar, you will have to add rebar manually in a cad detail or section . not automatic
  19. no the beta is gone, just remember if you draw any plans in X12, you want to continue but change your mind and don't upgrade you will not be able to open that plan in X11
  20. if you have manual roof planes and don't want to disturb them ,just copy your plan ,open that and use the auto roof planes, then copy the roof planes just for that area back to the plan.
  21. You might want to try an give the "PBR" a try. much fester