Greg_NY61

Members
  • Posts

    858
  • Joined

  • Last visited

Everything posted by Greg_NY61

  1. 3D warehouse has a huge Simpson hanger collection made by Simpson manufacturer.
  2. If you saved the plan and you still have the plan open in CA it will not upload.
  3. You can also create a line style with CRWN text to indicate what that is using smallest dash line settings.
  4. NP Ken, enjoy! Thanks you also have a good TG!
  5. There was a bunch of things on top of one another. This is should be fixed now if you didn't figure out by now MORGAN_AS_BUILT.plan
  6. Steve did you try making a manual stair select follow stairs and converting that to symbol and putting on top of the sloped wall. It's a little time consuming but works out good. That being said, you right, stairs need total overhaul in every way possible.
  7. If you copy one of the rafters do point to point and move to the the end of the ridge, select that rafter and swap dimensions the depth will be 1 1/2" and width will be 9 1/4" and make adjustments. Here is the plan ROOF fix.plan
  8. I made it in Sketchup. For some reason they don't have gas valves and no other 3D site has them (have no idea why).
  9. I made you one, I hope it will work for what you need. Gas Valve.calibz
  10. Here is a symbol if it helps. It can be made bigger or smaller whatever size you need. Exterior Corner Column.calibz
  11. I couldn't agree with you more Scott!!! I got them as well and they rock.
  12. Looks good Bob,, nice design, I love the kitchen details!!!
  13. I was messing around and made that in Sketchup real quick and imported as a symbol just to see how it will look, in CA a door opening will have to be made first and some adjustments will needed... It was made in CA 7 version Custom Archway.calibz
  14. I agree with Jeff, someone will lose his mind trying to sort this out and figure out what's what.
  15. Check your active filter, make sure Not Filtered is selected.
  16. You don't attach them to the interior, you screw them in into the plate from the outside same as you do with DTT1Z. They adjustable and can be moved up and down, in and out.
  17. We use now ADTT-TZ Tension ties much easier to use and easy to adjust in any situation. They come in flush or full extension and they exceed 2015 IRC lateral attachment requirements, just have to check with your building department if they heard about them yet, because some of the building officials have no clue, so you have to provide them with literature.
  18. Thanks for sharing... But you have to make some adjustment to your detail, DTT1Z Deck tie must be attached to the sill plate not the rim joist.
  19. Is this what you trying to do? Barn Copy 1.plan
  20. Thanks Joe! You right in time with this.
  21. Thank you Jon! Nice piece of furniture will definitely use it.