Kbird1

Members
  • Posts

    11494
  • Joined

  • Last visited

Everything posted by Kbird1

  1. If you don't want them to show up at all? .......... disable them in Preferences...... see pic. Don't forget to do your Signature Please.... the Software Version in particular makes a difference on many answers, ie X7 is very different than X10. M.
  2. Instead of using invisible Walls you can just use Stair Landings also, they will/should auto connect to staircases as well, and can have railings and nosings on selected edges. Mick.
  3. It doesn't appear you have an ..ELECTRICAL Power Layer defined , you do have and ..ELECTRICAL LIGHTING layer defined though , I think you maybe mixing Annosets and "Layer Sets " and just single Layers up.... Single Layers>Layer Sets>Annosets Set anything Power related to your new ..ELECTRICAL Power Layer (make it 1st) and anything Lighting Related to your existing ..ELECTRICAL LIGHTING Layer in the Defaults. This only covers the Default Items , so you will also need to assign other Objects you use to one of those two Electrical Layers too ( copy CA Objects to your User Library and change them there, if they are Items you will always use.) Your ELECTRICAL SET is still displaying a number of Lighting Layers and the Lighting Set is also showing some Electrical Layers you may or may not want on by default. You have a number of different Electrical and lighting layers ,( fixtures and furniture etc) so that will/may complicate what you want to see in what View (Electrical vs Lighting Annoset) M.
  4. Yep Bleed...., always build a Roof (or second story) and a Foundation even if you Model doesn't need one , CA uses them to "bounce" the light around in Raytrace and PBR views to some extent. I have also seen issues with Wall Definitions causing this in some plans posted here..... eg using interior walls for exterior walls M.
  5. AFAIK not a particular setting , just for Temp Dims , they use the currently active dimension settings I believe eg 1/4" scale etc , but the situation you are talking about is always an issue , there have been other posts with frustrated Users asking about Temp Dims too and what / how they locate objects.
  6. Tommy is in Houston , he maybe able to help.... Tommy Blair Houston, Texas V8 thru X10 Leader of Houston User Group tblair55@sbcglobal.net 713-467-0579
  7. I think anything before X6 requires a Full Re-buy now but you are right they do often have 10-20% Off at Xmas. You can also Rent Monthly now ($199) but it does work out 20% more expensive after the 16 month Rent to Own period
  8. Chief's Preferences show the OpenGL Render , RT is not OPENGL AFAIK as RT is mostly done by the CPU not the GFX card so if the UHD 630 is not disabled , during RT it is possible I guess the system is dropping back to the Intel Card..... you could try adding CA under the 3D Manage TAB of the NV Control Panel Did you upgrade the Intel GFX Drivers with the new CPU? I seem to remember other reports like this associated with the Intel card when X10 came out???? The latest NV Driver is not always the greatest ....the 400 series was released for the 2000 Series cards and aren't great from all reports I have seen , it is why I went back to 399.24 Does your MB fully support the i7-7700K? does it have the latest Bios?
  9. VideoCard Driver Issue? ..............Chief was using the 1060 not the Intel iGFX card right? all good here........ I am back on Nvidia 399.24
  10. I think Lew has stated before that you can "donate " old HASP Keys to other Users but best to call Chief and confirm .....though Lew may pop in here too and know the SOP. @lbuttery
  11. I believe Ray is correct , if you pull the Roof plane back to the inside of the exterior wall it may even popup on it's own? you should then be able to edit the Wall shape , pull it up , slope it, etc as needed, you may not need Chief at all to do that. Best to post questions like this in the Q&A section, as this section is for providing Tips , not asking for one..... M.
  12. sounds like you ( or someone) changed the Color Off Option in Preferences to gray scale
  13. Kbird1

    Section

    I think you need to provide some Pics or better yet a plan that it is happening in, as I am not sure I have ever seen what you are talking about. We also have no Idea what software you are using...... It's good to have your Forum Signature filled in, especially with the Software Version, and of course a real Name is nice too .............. See mine below in Blue for how to do that. If you don't see my Signature then you have them turned off for the Forum so you need to Toggle it on by going to the Upper RH Corner of this Forum Window and Clicking on your Username and making sure Signature are enabled (green) and then Add your Own Sig. too : UserName> Account > Signatures M.
  14. The sub-fascia/fascias are indeed set incorrectly , one side has the sub fascia bigger than the fascia , though the roof pitches seem to be the same so I just set both sides up the same and it looks okay, I think, without digging deeper into your Roof Structure .....I assume you are trying to simulate a metal flashing over the Subfascia since the fascia is set to 1/8" ? Chief doesn't handle that well as it auto applies the Soffit to the bottom of the sub-fascia and since it is 3/8" thick , your metal "Fascia" will need to hang lower than 1/8" past the sub-fascia, 1/2" should work.... see the pic for the settings I used below...
  15. Use Wall Material Regions for a more realistic Tile Installation , you can set thickness etc so I think it looks better , it's also fairly easy to do feature Bands this way too. Set the tile so it doesn't cut the parent surface/object...ie it sits on the drywall/backerboard as in real life. M.
  16. You can set the Backdrop for each Camera Type in Defaults>Camera Tools in X10 it's good to have your Forum Signature filled in, especially with the Software Version, and of course a real Name is nice too .............. See mine below in Blue for how to do that. If you don't see my Signature then you have them turned off for the Forum so you need to Toggle it on by going to the Upper RH Corner of this Forum Window and Clicking on your Username and making sure Signature are enabled (green) and then Add your Own Sig. too : UserName> Account > Signatures M.
  17. Kbird1

    Vray

    Many have switched to Chief's PBR Views in X10 , But we don't know what you're using since you didn't do you Sig. It's good to have your Forum Signature filled in, especially with the Software Version, and of course a real Name is nice too .............. See mine below in Blue for how to do that. If you don't see my Signature then you have them turned off for the Forum so you need to Toggle it on by going to the Upper RH Corner of this Forum Window and Clicking on your Username and making sure Signature are enabled (green) and then Add your Own Sig. too : UserName> Account > Signatures M. *** Chief's two videos on PBR ( Physical Based Rendering) https://www.chiefarchitect.com/videos/watch/2412/3d-rendering-features-added-in-x10.html https://www.chiefarchitect.com/videos/watch/2426/physically-based-rendering-technique.html
  18. You didn't close the plan in CA Joey before you zipped it so the Zip File is empty ( size is 1KB is a sure sign) as CA locks it while in Use.
  19. Winders are what you are wanting is my guess , just keep in mind many jurisdictions don't allow them to come to a point on the inside and may have a minimum of 6" at the wall and 12" at the Walking line.....check that locally. https://www.chiefarchitect.com/support/article/KB-00884/creating-stair-winders.html
  20. Yep looks better with that Stone on the Wall , it appears to have "depth" now , you could add a Cap to the stone-work as done Onsite , eg Sloped Concrete , easily done nowadays with the Wall Cap Tab for the Pony wall , Sill-01 in the CA Library works pretty well ( 4"x5" with a negative horizontal offset -2" ) or you can make your own Profile and Use it , if you need to do Section views etc. M.
  21. Nicely done Alvar , the starry sky is a nice touch.... One suggestion would be a nicer Texture for the Stone wall and perhaps a bump map for it , a BM for the sidewalk would help add to the realism too. M.
  22. A guess would be that you didn't Import them as Electrical Items>advanced>switched etc and perhaps used "Interior Fixture" instead? Attaching the .skp files to a post would be easiest for someone to check for you...
  23. If you Have CA X10 Premier you have PBR if you are using CA v10 then no, as it is a 10-12yr old program.... X10 is actually V20 (X being Roman numeral 10) and PBR was new this Year Mick