-
Posts
11503 -
Joined
-
Last visited
Content Type
Profiles
Forums
Gallery
Everything posted by Kbird1
-
So the material is that building's Siding? , I did not pick that up from the material name or the Material Image , I was looking at the Red Tile in the Image .... but thanks
- 25 replies
-
- ribbed metal panels
- textures
-
(and 1 more)
Tagged with:
-
Why would you quote a 4 year old post about a missing floor to ask about sloping Walls? ..........which by the way CA can't do.... Post your Own questions over in the Q&A Forum.... M.
-
they work pretty nicely for quick and dirty false Beams etc with the Sloped Soffit Setting but as Perry mentioned you don't see Moldings once they leave the horizontal plane and you have to check ignore Room moulding too as they will only follow the Plan View shape of the Soffit on the Horizontal too even though the soffit is sloped.
-
Hi George , thanks for this , it looks really nice .... question about the 1st post .....what is a Mini Micro? what am i missing in the images above?
- 25 replies
-
- ribbed metal panels
- textures
-
(and 1 more)
Tagged with:
-
Roofs are one area where HDP and CA Premier functionality are the same , but you'll need to post the .Plan file to the Forum , so we can really see what's going on , and any pics you have of the Original home if it's being rebuilt the same....images from SU would help if you have it right there too. M.
-
That works , that's how I do it when needed... M.
-
Sounds good to me as like others here I mainly used the standard 4 or 5 previously , so I guess we need to make a Suggestion Thread and maybe a lost functionality Report too. M
-
Yes the break Marks on a Terrain were a 1st for me , thought that must be an "Oz thing" Now that is funny about the BBQ ! that would be one embarrassed Brickie... Oh and Neil if it didn't come across in my previous Post I actually thought it looked pretty good ...try the terrain at about -3000 or -3200 , (depends how many, if any, steps you want on the High side of the house ,maybe it's correct already?) then you need to rebuild the deck framing to get it to build down to the sloping Terrain. M.
-
Is there a reason for not using your "Normal" walltype eg a 4" Brick and 1/4" plaster both sides ( I assume plaster not drywall ) if that is what is really there? I am wondering if Chief is not understanding the Materials in the definition as Drywall would never be the main wall layer and I have seen issue before where people have made the wall's main layer a Color eg white and weird things happening. Chief won't allow Rooms and hence Room Definition on the (A) Level , it won't stop you drawing the wall but it does give you a Warning message when you do this. This would be best , and as we only need the structure you can , in a copy or you main plan , delete things like furniture , cabinets, appliances, imported symbols , arch. Blocks etc ........ The Edit>Delete Objects DBX should help to make this pretty fast. M.
-
I have found over the years that Chief's Patterns are badly scaled , some need to be set at 10 , while many others I have used at 0.1 , it's a bit of a crapshot in that respect. Since they are now in the Library though , we can now Open them with a right Click and reset the Scale for permanent use fairly easily it seems. M.
-
Lets put it down to lack of sleep and general excitement over X11 https://chieftalk.chiefarchitect.com/topic/21339-x11-missing-patterns/?do=findComment&comment=174239
-
Have you tried working through the Tutorial Guide? link to the PDF in the Help Menu. There are also books Like Terry Munson's that he has been updating for a number of years now. https://chiefapprentice.com/ No sure how this plan came together Neal but in this one each CAD line has 8 copies sitting on top of each other.... The house Elevation doesn't appear to be correct, it looks like it is Floating so the Terrain reference height is too low I think. The Deck framing and Footings are what made me look closer , and either the terrain is too low or you need to regeratet he deck framing so the Pilings reach the Terrain. Typically if you want to use two plans you would make a symbol out of the House and then use that in the Plot Plan for Siting purposes as it is a Locked Block so to speak and can be moved at will. Have a look on the Edit Menu>Edit Area> and you will find different Options for Copy/Pasting Groups of Objects to other Plans etc. You better allow for a Lawn Sprinkler system that grass is looking awful brown Normally for ease of Drawing you would leave the house vertical on the Screen and rotate the Plot etc , it is very cumbersome to draw with the House itself Rotated. M.
-
Automatic walls only usually appear on the Attic level (A) and you shouldn't be drawing walls and making rooms on the Attic (A) level if that is the case?
-
This wall definition is wrong , your main layer is 3.5 inches of drywall.... Please expand the dialog and let me see it all like this...... M.
-
The walls look very thin , are they exterior walls ? what does the Wall definition look like? it very difficult diagnosing something like this from Images alone... M.
-
6 posts above , now with a Red File name so you can find it... M.
-
I don't think so as the Custom Option is gone , you now need to import them into the Library 1st by the look of it. But you should be able to Import any AutoCAD etc one's you have and apply them from the Library instead.
-
Try the File I uploaded above , its all the old Patterns (280) from x10 imported to X11.....it doesn't include the old STDs though AFAIK.
-
Joe and I both have the new Library Items but they don't include the Old Standards for some reason ( not a good move in my book ) but I had forgotten about the Pattern Import Function, thx. these are Chief's Patterns from X10 , from the Patterns Folder for X11 MHD Chief Fills Pre X11.calibz M.
-
Controlling what shows in cross section views
Kbird1 replied to BillsburgChief's topic in General Q & A
Not really sure what you want to see but in the 2nd plan you posted all I did was turn on the back clip for the view (Elev.7) and built the Wall Framing....., then hit Auto detail........the Rafters were already 11 1/4" so I don't know where you are seeing 15" ( your 1st plan in the OP has no cross sections in it at all btw) -
Angle Cross hatch is the one I said above...... Grid at 45° Grid is Cross Hatch Angle Hatch is Strip at -45 or 45° ( for left/right angled hatch) Make them all once and save to the library and you should be done in 5 mins?
-
Grid at 45° I think it is now , but you are right most of the Basic ones we had before we now have to make, there is no Custom Option either anymore, so I am not sure how we access the Pattern in the Pattern Folder....
-
they are in the Library now and you can save any custom ones you make to the library too.....
-
Is there anyway to control 2D & 3D symbol sizes on schedules?
Kbird1 replied to zowie123's topic in General Q & A
Thx for that Tip.... just to be Clear it is not available in all schedules.... just those with 2D Symbol available . Per the Help File..... In Electrical, Fixture, Furniture, Note, Plant, and Wall Schedules, check Use Plan View Scale to apply the same scale used in plan view to the 2D Symbol column.