You could also use different Reference Layer Sets to display the additional items.
-
Window Labels & Schedule has doubled quantity of windows
Joe_Carrick replied to CTB_Russ's topic in General Q & A
You have 2 Window Schedules. One is probably in a CAD Detail Window and the 2nd one is probably on a Floor Plan. The second possibility is that you have one on the 1st floor and one on the 2nd Floor and both are showing all the windows (All Floors) Find the second schedule and delete it. -
I use Vents from the Library - copied to my User Library so I can find them easier (as well as edit their properties). I don't use louvered windows as Vents. I do have a separate Schedule for Vents and I identify them as Foundation, Garage & Attic as needed by putting a code (F), (G) or (A) in the OIP.
-
How to add a 36" railing on top of retaining wall?
Joe_Carrick replied to JECORMIER's topic in General Q & A
I think you can make the retaining wall "No Room Definition" and then move another Railing Wall to the same location (center on the retaining wall). I'm not sure what other ramification that will create but you will probably have to play with the railing height and the bottom rail above floor height. -
How to add a 36" railing on top of retaining wall?
Joe_Carrick replied to JECORMIER's topic in General Q & A
Here's one possibility: Use a Molding Polyline for the railing. You can apply 2D Molding Profiles and 3D Molding Symbols to make up almost any conceivable railing. -
It really depends on where the ledger is relative to the top and bottom plates of each floor. Sheathing has to be continuous from the bottom of the wall to the top of the wall (plates). If the ledger is not at a floor platform then the ledger would be applied over the sheathing.
-
Does anyone have a symbol for a "Smart Panel"? In case you don't know what this is, it's similar to an Electrical Panel but just for installing CAT5, & Coax Distribution. (TV, Ethernet, Security Systems & Phones). Usually it also has a built-in 110V outlet for plugging in routers, etc. There are LowVoltage connector blocks that can be snapped into the Smart Panel. I could just create one, but maybe someone already has so I'm just asking. Thanks
-
How to rid gutter/fascia on part of roof plane? Image Attached:)
Joe_Carrick replied to zowie123's topic in General Q & A
This is simple. Unlock the Roofs, Gutters layer Select the edge you want to suppress the Gutter Click the Remove Molding from Selected Edge tool. OOB, Chief has that layer locked - but unlocking it allows you to make edits just like any other Molding Polyline. -
How to include new cad solid in material list
Joe_Carrick replied to Doug_N's topic in General Q & A
Yes, but for the purpose of dimensions (Framing Objects for the OP) it's not going to do the job. -
How to include new cad solid in material list
Joe_Carrick replied to Doug_N's topic in General Q & A
OK, I wasn't aware of that but is there really any way to get them to be reported as anything usable in the Materials List? They don't have a "Components" dbx. Only by creating a Symbol out of the solid can you get "Components" to assign data to for comprehensive Materials Listing. -
How to include new cad solid in material list
Joe_Carrick replied to Doug_N's topic in General Q & A
Doug, Solids and/or CAD are not included in Material Lists. Only Architectural Objects (Walls, Doors, Windows, Cabinets, Floors, Roofs, etc) and Symbols are in included in the Materials Lists. For your Pool Structure you should use Wall and Roof Framing (steel framing) to get those items included in the Materials List. Just take the time to set the framing defaults, wall types, roof structure, etc and then "Build Framing" for those items. Also note that only layers marked as "M" in the Layer Sets will be in the Materials List. -
How do you Remove/Delete a Stair Section
Joe_Carrick replied to lavorhaynie's topic in General Q & A
Ctrl-Click the stair section you want to edit/delete to select just that section. I'm not sure if deleting a single section will cause everything else to automatically adjust - you might need to do some judicious editing in the dbx. -
Just to be clear, Both Michael, Perry & Scott are correct. The Active Defaults control almost everything. Annosets specify what the Active Defaults are to be - essentially a 1 click way to set/change the Active Defaults. When Perry & Scott say they don't use the "Active Defaults" they are just saying that they don't select the "Active Defaults" tool to make changes. They rely on selecting an "Annoset" to make those changes. This is the way I work as well. If we need another set of Defaults - we create a new Annoset which may require additional Layers, an additional Layer Set and maybe additional Text Styles. I've been doing this for quite a while and everything is in my Plan Templates, so I seldom need new Annosets. Occasionally a special condition makes it necessary. Typically, I have the Text Style in the Annosets set to use the Layer Set Text Style. That's the one place where I use the Layer Set to control the annotation - but the Annoset sets the Layer Set and the Current CAD Layer. I'm scheduled to make a presentation on this subject at the UGM. I'll know in a couple of days if I will be able to make it to the UGM. My wife may have to have spinal surgery and if so it will depend on when that happens. It may present a time conflict for me.
-
AFAIK, it defaults to the scale of the current drawing (view being sent to layout). I don't think there's any place to set it to be anything else as a default.
-
There have been more. I got 8 for my Pocket Door Symbols - but it took about 3 years to get that many. I think Wendy got more than that for her Layer Set Video. IAE, 6 within just a few minutes is really amazing.
-
You will get more results by posting in the Q&A Forum. It's a common mistake that new users seem to make - posting in "Tips & Techniques". Look at the explanation below the Forum Heading to see what the purpose is of each Forum. IAE, in order for anyone to answer you need to state the name of the software and what version.
-
I'm in agreement with Scott & Perry. There are cases where the wider footing works best and other cases where a Pier/Pad works best. If the pad is thicker than the footing, I use a pad and set the fill to solid and adjust the display layer down so the foundation wall shows thru. IMO, this is a situation where it's easier to manipulate the graphics than to have the CA software engineers try to make it automatic. There are just too many variables and I am afraid of too much "automatic".
-
Make the lower wall a single thickness (6"-8") of Marble.
-
Stairs, will be the death of me in this program!!
Joe_Carrick replied to CutAbove's topic in Tips & Techniques
Tips & Techniques Share your favorite tried and true methods for solving custom problems using Chief Architect. That's what it says at the top of this forum. I think that's pretty clear. OTOH, At the top of the General Q&A forum it says: General Q & A Ask Chief-related questions and get answers from experienced users. -
Stairs, will be the death of me in this program!!
Joe_Carrick replied to CutAbove's topic in Tips & Techniques
Why did you post this in "Tips and Techniques" instead of "Q&A" where it should be? -
Convert to a "Custom Countertop" and you can make it any size/shape you want.
-
Jared, For Beams and Posts you can set defaults for the Labels (x,y offsets and angles). For Joists and Rafters I group select - then adjust the Label offsets (x or y). You can also modify the Text Style for the any of the Framing Layers to make the Text Background Transparent or Not-Transparent. It would be nice if all this stuff was consistent and had Defaults like the Beams and Posts - but it's still doable currently.
-
Can you do my face?
-
Lag, Hangup, Pausing while Deleting Objects or Undo
Joe_Carrick replied to Jarr3tt88's topic in General Q & A
I am still using X9. I don't think XX will be available even for Alpha or Beta testing until after the UGM. What part of my statement doesn't agree with your observations. I would be happy to test your scenario and see where I have missed. IAE, the "Edit/Undo" times are dependent on what potential changes have to be made to the entire model, not just a single element. If Chief somehow knew what the limits of the change was, it would be possible to update just those things and be much faster. Currently I don't think that would be very easy for CA to do. I won't try to explain how Chief processes Edits and Undo (I leave that to Dermot or someone else at CA) but the basics are that the model state(s) are saved and are available to reload. The size of the model, type and amount of ram, access speed, CPU speed, and possibly disk read/write speed for the swap file can all effect these operations. It's not just one thing. -
Lag, Hangup, Pausing while Deleting Objects or Undo
Joe_Carrick replied to Jarr3tt88's topic in General Q & A
Note that there are no "Wall Details" until wall framing has been built. Once a wall has been framed, the "Wall Details" are live and will automatically re-build even if you deselect it in the Build Framing> Wall DBX. I suppose CA could change that but the logic to it is simple. If there are existing "Wall Details" that represent the framed condition of a wall then changes to the model need to change those Details. Otherwise those could easily be out of sync with the model. Any editing of a wall (move, insert or remove openings - move a wall - change floor heights - change ceiling heights - etc) means that all wall framing in the model needs to be updated. There could be connected walls that also have to be changed. In theory it would be possible for the software to recognize where connection exist and only change what needs to be changed - but that could be a very complicated programming job requiring a lot of changes to the database. if you select each wall and select "Retain Wall Framing" they will not re-build. That could speed up the edits and undo's but it would also eliminate the accuracy of the framing. The best practice is to wait until the Plan is complete without framing. Then build the framing and make any changes to that as needed. Sometimes that's not practical, but that's how I try to do it - at least for walls. Actually, there are similar issues with all sorts of inter-dependencies within a plan. If a wall is moved even a fraction of an inch, Cabinets, Electrical Outlets, Switches, Doors, Windows, Niches, etc have to be moved as well. Even Room properties and their labels may need to be modified, not to mention dimensions. It doesn't matter if changes are made in 2D or 3D Views and it doesn't matter if any element of the Plan is not displayed. Changes to the model involve the entire model, not just a part of it. Everything has to be updated unless it has specifically been "Retained" and then you run a severe risk that the ConDocs will not be correct. Computers are much faster than hand drafting - and we get spoiled. Just think of what you had to do 20 years ago. You made a change and you had to erase something and redraw it. You might have needed to change several drawings and a lot of text, dimensions, etc. The fact that it takes a few seconds to make such changes is much better than minutes or even hours.