lavorhaynie

Members
  • Content Count

    75
  • Joined

  • Last visited

Community Reputation

10 Good

1 Follower

About lavorhaynie

  • Rank
    Member

Profile Information

  • Gender
    Male
  • Location
    Tulsa, OK

Recent Profile Visitors

726 profile views
  1. lavorhaynie

    Settings: How to set move increment

    Got it. Thank you Chopsaw.
  2. Been searching for a while now and cannot find it... How do you set the move increment value. By default it is 1". That means, after selecting an object, I can hit an arrow key and the object moves 1" per hit. I need to change it. Thanks!
  3. lavorhaynie

    Any idea where this plywood decking is coming from?

    Rob, I shut off the "No room definition" on the garage back attic wall, leaving the "Attic wall" and "No locate" options selected. That resolved the issue. Thanks! Will send on to the client now. This appears to be an issue with the software but it does have a simple workaround. Thanks all!
  4. lavorhaynie

    Any idea where this plywood decking is coming from?

    Glenn, I checked ceiling heights and all are correct. All house, porches and garage are to be 121 1/8". Note that the front porch is the same structure as the rear porch but it does not exhibit the same issue.
  5. lavorhaynie

    Any idea where this plywood decking is coming from?

    Michael, that is what I thought but there is no room defined in any of the highlighted area on the second floor or attic.
  6. Where is this ply deck coming from? See pics. The highlighted ply is highlighted using the "Delete Surface" tool. Plan file backup is also attached. The plywood decking spans over three rooms, porch, breakfast and a portion of the garage. Thank you for sleuthing this. Any help is much appreciated! LM27BU.zip
  7. Does anyone have an efficient procedure for changing a foundation from one type to another, i.e. a monolithic slab to a crawl? I typically end up deleting the foundation and starting over. Thanks!
  8. Thanks guys!. Got it. Did not know about the need to convert. All done, looks great!
  9. I have been trying to create a poly-line solid as shown below in the attached picture. I have tried manual editing of surface lines and poly-line subtraction with absolutely no luck. Any ideas/help would be greatly appreciated.
  10. How do I adjust the ceiling joist width for a single room? I see where to adjust it for the floor default but cannot find how to do so for an individual room.
  11. lavorhaynie

    Style Palettes and Mulled Windows

    Is there a way to apply a style palette to windows within a mulled unit?I have simple window twins and triples which I would like to change using the style palette tool but cannot.
  12. How do the experts deal with this? Second floor exterior wall with a sloped roof plane against the wall. Wall passes by the roof plane and becomes an interior wall. How do you change from an exterior wall with siding to an interior with drywall, following the slope of the roof?
  13. lavorhaynie

    Monolithic Foundation Wall at Porch

    Steve, Thank you for the information. It worked fine. Thought I had tried that setting before but must have not. I am still debating whether I will do a foundation wall or point footers under the columns. So, currently I have both the porch room and the extended slab in place. I will eventually eliminate one of them. Thanks again and have a super weekend!
  14. I have a plan with a monolithic slab foundation. It has a large porch with the floor dropped 4" from the main floor. The porch uses a monolithic footer, supposedly stepped down (4") from the main foundation. How do I get the step-down to model properly. Currently the porch foundation maintains the main floor elevation as seen in the attached picture. Also, in plan view the porch foundation wall does not have the same visual characteristics as the house foundation wall, as can be seen in the attached picture. I also attached the plan (X11). Any suggestions and help would be greatly appreciated. This is a preexisting A-frame with the two wings to be added. A-Frame.zip
  15. lavorhaynie

    Switched Outlet Symbol

    I need to specify a duplex outlet with the bottom receptacle hot and the top receptacle switched. What is the proper 2d symbol to designate this on a plan? Thanks!