  1. unless you fully understand all the things needed in an electrical load plan and a plumbing diagram, have your professional electrician or plumber help you lay it out.
  2. Your driver date is old try a newer version, they release new drivers about every month.
  3. I think its a bug, used to work good. turn it in to support.
  4. Did you uncheck merge co-linear walls before breaking the walls and setting the pitch. It should be 3 separate walls. works for me
  5. you also have to tun this off after breaking the wall and changing the pitch
  6. look in the wall DBX, there you can add any pitch you want different than the default on a wall-by-wall basis.
  7. just build it with stem block walls and check slab on top.
  8. two of your new walls were listed as attic walls, change them to normal walls and uncheck no room definition and no locate, then you will get a roof and a floor.
  9. Post the actual plan file so we can see what you did. I have done thousands of additions without any problems, it might just be how you put it together or settings. it would also be easier to read if the new and existing walls were different color fil.
  10. You should use reference layers to see anything not on the current floor, go to chief's website and watch the videos
  11. Go to Chief's website and watch all the videos.
  12. make sure you turn on the monitors first then start your computer. I have a similar setup. it always starts on the left one first then switches to the right. Mine are also set to the same resolution and 4k
  13. try to open the material and change the line color to black, and increase the weight.
  14. I have drawn many plans in X16 without any problems a lot of them were brought forward from x15 preliminary plans.
  15. the room needs to be an open below room
  16. Create a custom countertop for that island and just break it and drag that end back.
  17. Yep it's also required here in California but also almost everything must be engineered here also so all that is on his calc's and drawings.
  18. nope if it's not a chief 3d model. you didn't say what kind of file you want to import.
  19. Need to learn everything about glass railings, codes, cad details, ICC approval? today from 11-12PT. AIA certs. very informative. If you can't make it, they will send you a replay. Direct from the manufacturer. sign up here https://lnkd.in/e2GNr5Fj
  20. I believe its a re-generate your terrain notice.
  21. i always have a second floor in my templates and even have a box second floor plan in my template plan . It makes it easy to delete if I don't need a 2nd floor. I would rather delete than add.
  22. or if you need the upper wall, make the upper wall invisible
  23. We used to be able to adjust the footings independently a few versions back, but now you can't very easily. not sure why it went away. It was really easy to manipulate the footings for pads etc.