  1. I believe the Lapse Policy is only available for 30 Days after the Lapse ( ie a late payment ) but also only applies if the Current Version is still active , which is probably why they are charging you for an Upgrade now because X10 has been released. ( Feb 15th )
  2. Did you try the Ignore 2nd floor setting in the Build Roof DBX? ( or 3rd floor etc depending which floor you need ? ) https://www.chiefarchitect.com/support/article/KB-00653/building-a-cape-cod-roof-that-bears-on-the-1st-floor-walls.html
  3. I saw this Reported in Beta , but don't remember the Fix off the top of my head.....I will try and look later if you don't get a Fix from someone else there is an error of extra Trusses being generated too in some Plans that Michael ( @Alaskan_Son ) found too
  4. Should be all good tomorrow then when you Call Customer Support..... https://www.chiefarchitect.com/company/contact.html
  5. They have changed how that Setting works in X10 ( or it actually works properly now? ) so people are having Issues with this Setting as it did not need changing in X9. So it's a TIP https://chieftalk.chiefarchitect.com/topic/16849-slab-through-wall-walkout-basement-was-okay-in-x9-not-x10-beta/#comment-141745 https://chieftalk.chiefarchitect.com/topic/17096-foundation-wall-step-down-issue/
  6. That's about it for me too.... I've not seen this issue before though with Dims , so slow to populate....
  7. really slow in Elevation though other views didn't seem bad , eg 3D overview was okay.... Tried a side and back-clipped Elevation to one building and it was a (very) little better... you and I have the same VideoCard so I don't think it is that....
  8. The plan is Really slow George , at least for me , so you have to drag REALLY slowly or I think I get the craziness you describe.... either Vertically or Horizontally using the Manual Dim. Tool , vertical seems worse...I wasn't sure what Mode you were using from the OP..... and you didn't save a Camera either , so I'm not sure if it a particular Camera you are using... by default you Elevation camera ( Annotation) was Using 1:1000 Scale (numbers were huge) which made it worse .....1:50 Scale was better..... tried smaller too I didn't download all the textures in the Folder , not sure if that is my slowness issue ? or not.....assuming you don't see that it maybe... *** redownloaded entire Folder but no difference. M
  9. Are they both the Same Camera Type ? check the ALDO and make sure all Camera types are displayed in Plan View if you use different Layers for different Cameras as I do... Also some cameras can be set to only display on certain Floors.... M.
  10. You Zipped your Plan while it was Open in Chief , so the Plan file is 0kb as Chief Locks the File while it is Open. Re Zip and repost if needed... M.
  11. I posted about this Issue in the Link below , X10 is not updating the Default File Types to X10 when it Installs so I had to do it manually...
  12. 2016 would explain why the Upgrade to X10 is not Free but I don't think x9 was available in 2016 ( Feb 2017 I think? ) but SSA may have expired July 2017 if you purchase July 2016 but that SSA would of given you the Free Upgrade to X9 but no further .....your Digital Locker tells you when SSA Expires right under the Serial No#. M.
  13. I think the trick you need that will work in X3 is to actually do a Blank 3rd Floor (same as the 2nd Floor in the Tutorial) , so you can cantilever the Landing and the "Deck Walls" won't interfere with the 2nd story Walls , then change the Wall to Railings, , 2nd story will be 12" ( same as beams) 3rd story is set to Handrail Height, like this : M.
  14. Best to use Pics here , people don't always like downloading Files to their Computers from complete Strangers..... From your PDF.....
  15. Probably best to post some images of what you have and are trying to do , , or post a copy of your plan so Others can have a look. We also need to know what software and Version you are using at a minimum M.
  16. I assume you mean a Parapet Roof...there is a KB article on doing those here: https://www.chiefarchitect.com/support/article/KB-00295/creating-a-flat-parapet-roof.html Also, it's good to have your Forum Signature filled in please, especially with the Software Version, and of course a Name is nice too ..............see mine below in Blue for how to do that. If you don't see my Signature then you have them turned off for the Forum or are perhaps on the CA Mobile WebSite
  17. The Auto Joined Switches don't look good in PBR ,Vector view is a bit Better and they look Fine in Standard Cam. Views , so it will depend on the Views you want or if using PBR you can just Turn them Off in the View .... if on their Own Layer. Chief's switches in X10 , including the Half (Double) Switch seems to accept multiple wires ok so..... If you do use the Dacor Library note that Many of the Switches are at 11 1/2" by default to Centre, I will likely just copy the Library and set things right as Chief has them all in Bone too. If the Default material in your Template Plan is White it should override that when placed though anyway. Perhaps you should ask Legrand to make a Library for Chief ? they do 20/20 I think..... Lutron and Leviton both do screwless Wallplates too , not sure about costing on either though....
  18. Thanks for the Info .....might be an overheating Issue , get HWInfo64 or HWMonitor and check the Temps of CPU and GPU during RTs ..... I usually have CoreTemp in a side window if not one of the other two during RT. M.
  19. It doesn't seem in the Default template plan anyway , which I assume this is... , that it is working in any layer-set for framing. I tried it in 3D as well, and just turned off Ceiling Joists as a Test , and they are still in the ML ... it would seem they have broken the ML upgrading it or maybe this is how it is done now? Ie can only turn off assemblies eg a Whole wall , not it's components. M.
  20. it looks like you are Right..... If you do a Framing overview and click on one of those three joists you will see that the ML is still checked
  21. Yes that's what I do too since , even if I went to the Trouble of figuring it out they would not accept them as the Calcs are only accepted for Permits if done by a "Schedule A" Qualified Professional ie the HVAC/E.Eval Engineer and he has to do the Calcs. for all the other Air Handling anyway. ***OT Warning : Gerard how do you like the 1070 in Chief ? I was just informed this morning my RMA of my 980ti for Sleep issues , will mean I get a 1070 or 1070Ti instead and the specs seem lower than my 980ti ..at least on paper... M.
  22. You said you didn't want them to "snap" in the OP ? ... you can place them together but you'll have to do it manually / visually if you turn off the Auto Function. Perhaps post an Image of what you want, and someone with more symbols Skills than me can possibly help, but why not just make the 2/3/4 switch symbol the way you want it now you have it mostly drawn? You should be able to Change the CAD Block via the CAD Block>Insert into plan>explode it>change it >reblock it> assign new Block to Symbol method. https://www.chiefarchitect.com/support/article/KB-00805/editing-2d-cad-blocks-assigned-to-3d-symbols.html https://www.chiefarchitect.com/support/article/KB-00500/customizing-a-cad-block.html https://www.chiefarchitect.com/support/article/KB-00014/exploding-a-resized-cad-block.html
  23. I was thinking that would be a PITA to do everytime , hence the second symbol suggestion, with a slightly different label, which would be quicker to place, but maybe that's just me M.
  24. good way to fill in a Sat. Night maybe?
  25. or the Icon if you add it to the Toolbar ( if not there)