Kbird1

Members
  • Posts

    11515
  • Joined

  • Last visited

Everything posted by Kbird1

  1. Hi Zahida , your Image works fine , though I don't know the specifics of the Mosaic Tile? I guessed it was 18" x 18" in the Images below..... The image isn't great for "Tiling" across a Wall as it is brighter on one side than the Other and you can "see" that in the Backsplash every 18" particularly in STD View, PBR is better.... Mick.
  2. In the HD Titles, Stairs Railings for example are limited by the Template selected ( or used to be ) so you had to be careful starting a Template as you couldn't change stuff 1/2 way through like in Premier. Not necessarily at all , especially if you are new to CA and have yet to Develop any Templates of your Own , they definitely are not "fleshed-out" templates and will need alot of Changes and the big difference in Premier is there is no limitations as to what changes you can make. But there is no Template for Tract house or Contemporary or Victorian etc , you just have to be vigilante to save Plans as Templates and slowly create your Own "Styles" as you go. The KnowledgeBase has a few Articles to get you started on maintaining and Creating your Own , but I do suggest making a copy of the OOB Templates to another Folder as a backup, just in case) https://www.chiefarchitect.com/support/category/271/templates.html
  3. Because Home Designer Titles come with these Templates and by Default you must Choose one to Start a new Drawing, I don't believe that has changed since I used HD Pro before upgrading to Premier, 8-10 years ago. And I have never actually seen anyone using Premier ask about them or Use these templates , so I assume from my own use that HD User will have more knowledge of them and there uses...
  4. Most People with Premier build there Own template from the Default one ie Residental Template.plan and save their own Styles or use old Plans saved as Templates for different styles they usually work on. None will be perfect , there are just too many Defaults to cover. Your question may still be best answered on HomeTalk as they have no choice but to use one of the pre-define Styles or a Default blank Template and my guess is they could answer the question much more easily as they tend to start with one of the Pre-defined Styles. M.
  5. Hi, it sounds like you are using one of the Home Designer Titles? so it would be best to ask on HomeTalk not Chief Talk , as they would know whatever version of the Software you have. Same Username/password over there as here...... https://hometalk.chiefarchitect.com/?_fromLogin=1 Also, it's good to have your Forum Signature filled in, especially with the Software Version, and of course a real Name is nice too .............. See mine below in Blue for how to do that. If you don't see my Signature below then you have them turned off for the Forum, so you need to Toggle it on by going to the Upper RH Corner of this Forum Window ^^^^ and Clicking on your Username and making sure Signature is enabled (green) and then Add your Own Sig. too : UserName> Account > Signatures M.
  6. The Black Screens ( and White Screens (white-outs)) are discussed in the Lets PBR thread and were usually due to the Global Illumination setting and switching from Standard view to PBR AFTER the camera view was Shot IIRC? it is why I mentioned to have all that setup 1st ...I now have all the Defaults setup and PBR as the Camera 1st View Technique to avoid this in my Template as Mark mentioned. M.
  7. I wondered the same thing...ie are they current.... as the Chief Libraries mention the Files being in .alb format which I don't think has been used in 8-10 yrs? and Chief now has it's own Viking Corp. Appliance Library for free.
  8. Hi Z. You don't import the image of the Tile , you have to use it to create a new Material and then use the new Material for your Backsplash. However in the plan Posted above, you do not have a Custom backsplash in the Kitchen yet, once drawn in Elevation or a 3D View, you can then change the material to the one you created or any other in the Chief Library. Post the image of the Tile and I will try to make a short Video for you about the Material Creation.....
  9. Also, it's good to have your Forum Signature filled in, especially with the Software Version, and of course a real Name is nice too .............. See mine below in Blue for how to do that. If you don't see my Signature below then you have them turned off for the Forum, so you need to Toggle it on by going to the Upper RH Corner of this Forum Window ^^^^ and Clicking on your Username and making sure Signature is enabled (green) and then Add your Own Sig. too : UserName> Account > Signatures M.
  10. It's possible the Radeon is causing Issues , have you ever updated the Drivers? CA recommend NVida Cards but the Radeon should work as long as it support OpenGL ( it does) https://www.amd.com/en/support/graphics/amd-radeon-r7-series/amd-radeon-r7-300-series/amd-radeon-r7-m360 You are right RT in particular and PBR both require some time to learn , it is not a Push the button and Presto you have PhotoRealistic Renderings deal, but you should be able to get PBR's in particular that are "good enough".... make sure your Automatic lights is 100 and Global Illumiantion are set in the Technique and Camera Options , think I posted on about the 4th page of the Lets PBR thread about that.... You haven't supplied a Plan or any images to critique to hard to advise much more but in general terms.... Might be worth looking at this thread from friday too....at least the second page...Graham posted some nice Images there too https://chieftalk.chiefarchitect.com/topic/20014-manipulating-materials-and-lighting-help/
  11. Oh...forgot he was X8...... but only meant he shouldn't change the Default unless all Staircase were to be the same... This is how to do you own in Older Versions.... https://www.chiefarchitect.com/support/article/KB-00082/manually-adding-railings-to-a-staircase.html
  12. See my 3rd pic above , you need to Assign PANELS , not Balusters.... BTW ..........You are in the Defaults DBX ,not the Staircase's DBX M.
  13. 1.) Here is another tutorial and video on making the new material , there is no way from the plan to figure out what you are doing wrong and you have not supplied the Tile Image to test with either. https://www.chiefarchitect.com/support/article/KB-00767/creating-a-new-material.html https://www.chiefarchitect.com/videos/watch/38/creating-custom-materials-and-colors.html 2.) Either use a Series of Landings or Set your Stairs to Winders in the Staircase DBX but the Knowledgebase has many good Tutorials for stuff like this... https://www.chiefarchitect.com/support/article/KB-00884/creating-stair-winders.html 3.) glass panels for the modern look with acrylic handrails for stairs....have not seen this personally but you need to read up on using Panels for the Rails as you can't use an Image.... https://www.chiefarchitect.com/support/article/KB-01029/specifying-glass-or-cable-railing-panels.html https://www.chiefarchitect.com/support/article/KB-00082/manually-adding-railings-to-a-staircase.html Mick.
  14. http://www.chiefsymbols.com/ ( use Chrome, F.Fox page is messed up) I was not aware of these , I thought you were talking about CA's own CAD Files in their Library. You might want to update your 1st post and be specific about what 2D CAD Drawings and provide a Link etc so those who maybe aware of this Library can advise you. Did you request the Smaple pack ? are they good quality ?..... and current ie not detailing stuff done in 1982 ? there is no refund so you want to be sure.... of course it could be fully Worth the $299 but I can't personally help you.... M.
  15. The Railing Guy I spoke to recently said they make the plate twice the size of the railing , ie for 2.5" it was a 5" sq plate with 4 holes , he was using 3" Stainless 5/16 Lags and Washers...... not that that really helps you but you could likely find the Specs on the Lag Screws. OSHA has one I came across , not sure if it helps ...... osha-guardrail-details.pdf And Hilti has lots of info in there Concrete Anchors Technical Bulletins including some info On CMU Blocks. They might even be worth a Call Monday? Hilti Conc_Anchors_2.pdf Hilti_Conc_Anchors Technical.pdf *** Forgot to add the AWC has a Connector Calculator here : https://www.awc.org/codes-standards/calculators-software/connectioncalc M
  16. Looks good Graham..... One other thought Alisa , is that they have upgraded many of the Materials to work with PBR in x10 , so you may find things look even better with the new textures.
  17. I am none the wiser as to which ones you mean (A E C ?) but most of the CAD details on the 3D library have not been updated for 2-4 years , so there are no new ones if that is your thought? I now see you have X8 so you couldn't use newer ones even if there were some available. M.
  18. Search the Forum this has come up many times but this may help..... https://www.chiefarchitect.com/support/article/KB-00673/creating-corner-windows.html
  19. CAD symbols? If you ave SSA , they are Free..... you need to do your Forum Signature so we know what software and version you have.. *** to fill in your Signature like this .... go up to the top RH Corner above and click on your UserName> Account Settings> Signature.... and enable Signature (will Turn Green) then add your Hardware Details and Chief Software Version, as different Version require different Answers.
  20. Send the Test Plan in or they won't know there is an Issue........ M
  21. See Michael and My posts from Yesterday about the hidden Arrows https://chieftalk.chiefarchitect.com/topic/20000-individual-door-labels-x10/?do=findComment&comment=163387 Kirk's Video is also very good.....
  22. It's right there in the 2nd Post .... or just above now.... Lucky you Kirk just made a video in another Thread too....
  23. You must have Sigs Off , in your account settings, check it so it goes green..... see blue below for how.... you should see this : Mick CA X10 Win10 Pro on (3) 32" BenQ BL3200PT Monitors Desktop - Custom Built with Asus X99A-II MB, 5820k CPU, 32GB RAM and EVGA Nvidia GTX 1070 Ti FTW2 *** to fill in your Signature like this .... go up to the top RH Corner above and click on your UserName> Account Settings> Signature.... and enable Signature (will Turn Green) then add your Hardware Details and Chief Software Version, as different Version require different Answers. ***To add Pics to your Posts please use Windows Snipping Tool , found under Windows Accessories in your Start Menu, Save the Snip to your Desktop and Drag it into the Light Grey Area of the Reply Window.
  24. Depends on the type of Fixture Usually , ie is it concentric to the Box or hang down or point Up , so I usually use 78-84" depending on that and the Room Type etc, 72" must be a very old STD I think.
  25. That Default setting would only change the Fixture set as the Default Wall Fixture I believe..... The Default Fixtures are the ones in the Quick Electrical Dropdown only... The Library lights would need to be copied to your User Library and then the height can be Changed , and you wouldn't use the CA Library Core Item anymore as it is locked.(no changes) M.