I use a fence set to white 1" high
-
Bonus lib. shutters
-
widen foundation wall footing to support exterior post
Kenoeightspot replied to jimmyp's topic in General Q & A
Use the Wall break tool then pull out the footing -
Users should be able to adjust the order of the line styles. I have asked for this years ago. Fix this CA.
-
allowing window to span across intersecting wall
Kenoeightspot replied to rikdekker's topic in General Q & A
Dennis is correct. but if you have to move the window first pull back the wall then move the window. Add a polyline solid end cap. -
How To Control Site Plan Dimension Size
Kenoeightspot replied to HumbleChief's topic in General Q & A
Place the polylines or terrain perimeter on the layer that has the text style that you want. -
You may have "painted " your walls. Select the "spray can" tool, when the DBX opens check the "use default" in lower left then spray your walls, this will set them back to the gray default. Then change the default wall material to whatever you want. If this does not work post the plan so someone can look at the issue.
-
Has everyone noticed that regular dimension extension lines offset to objects. This will allow grid bubbles to be offset when two are close together. This is similar to the "story pole".
-
The method I use is snappable, it shows in 2D and 3D but it takes 5-6 mintues a room. A new tool from CA. would be best. I have vectorworks but like Ca better.
-
New and existing door and window call outs on the plans
Kenoeightspot replied to capitaldesigns's topic in General Q & A
Now uncheck "include in schedule" in the door/window DBX.- 8 replies
-
- door and window
- door
-
(and 1 more)
Tagged with:
-
New and existing door and window call outs on the plans
Kenoeightspot replied to capitaldesigns's topic in General Q & A
Type "EX." in the "Label options".- 8 replies
-
- door and window
- door
-
(and 1 more)
Tagged with:
-
New and existing door and window call outs on the plans
Kenoeightspot replied to capitaldesigns's topic in General Q & A
Uncheck "Include in schedule".- 8 replies
-
- door and window
- door
-
(and 1 more)
Tagged with:
-
Adjusting the texture/pattern is trail and error. It took me one minute per direction, but not perfect. 2D cad lines in plan for perfect alignment. Ceiling tool please.
-
Click on "Room Polyline" adjust ht. change material to ceiling tile. adjust the pattern and texture of the material as needed per room.
-
Joey, I like using "American Clay" They have four versions. I showed the four types.
-
Good information Thanks Perry.
-
Suggestions on how to make a plumbing access panel?
Kenoeightspot replied to ClarkeThrasher's topic in General Q & A
The Door/Cabinet method can also be used for wall access to crawl space or child's secret room. -
Suggestions on how to make a plumbing access panel?
Kenoeightspot replied to ClarkeThrasher's topic in General Q & A
Try a cabinet. Image of cabinet on left, door on right -
Suggestions on how to make a plumbing access panel?
Kenoeightspot replied to ClarkeThrasher's topic in General Q & A
The downside to this method is it will cut through the entire wall, not good if there is a room on the other side. On the good side it will show up in the door schedule if you want it to be included. -
Suggestions on how to make a plumbing access panel?
Kenoeightspot replied to ClarkeThrasher's topic in General Q & A
Small thin door without hardware or hinges, material same as surrounding wall -
Have the teacher start with CA. articles and reference material in https://www.chiefarchitect.com/green/
-
Your attic does not have a usable area above it so the 10' rule does not apply, but since it is within 5' of the property line the 10' rule may apply.
-
Since the deck is considered usable and you have a usable room below then you meet the definition of requiring draft stops. You need to isolate the deck floor assembly from the roof attic areas.
-
Scott, In your example is that a deck in the middle?. The inspector may think you are using open web floor joists. If your are using open web joists then draft stops are required every 1,000sf.