  1. One out of 1000 have an adverse reaction to Pfizer vaccine for COVID & they are still pushing it. There seems to be no standard threshold for risk.
  2. Are they sealed when in the up position? Crock-pot on the counter & the ladle gets out of control.
  3. I've never physically seen one, only pictures. My point is how water resistant are they. Spilling liquids like soup into the cracks & crevices will create a cleaning nightmare.
  4. So when you spill the soup down the receptacle, who is going to clean it out?
  5. I have found this site useful. https://www.userbenchmark.com
  6. I'm not very good at Sketch up & have an old version but if you have a 3d CAD file give me a shout.
  7. I used the Autocad file to produce the dae file. Deleted the drain & under counter piping. Faucet-Lavatory-Delta-Stryke-Widespread-Single-Lever_Handles.dae
  8. Great sleuthing mark! Here is the dae file I created. Faucet-Tub-Delta-Stryke-Roman_Tub.dae
  9. Thanks fellas, Thanks Michael, more versatile solution than a complete override.
  10. Try here: https://www.bimobject.com/en/search?fullText=locker&sort=trending&page=1
  11. Any way to change the default "Fixed Glass" to "Direct Set" in a plan? I can do it through Select Similar & override the description but if I change the type in the future I will have to fiddle with the description. The GC is overly picky.
  12. Bob, sorry to mislead you but this is a code question not a Chief question. Thanks for the reply. Michael, I think the 2x4 bracing is too thin by itself to be rated, maybe a 4x4 would, as timber is rated based on a char value. I've never used that method. I like the drywall wrap on the 2x. I looked for a foam or caulk but they are limited in there use. The problem is there is 300 feet of wall to repair. Some walls run perpendicular to the trusses. So the wood truss bottom chord is now the fire rated bracing member.
  13. See below as to how the wall was supposed to be installed but they attached the top track to the 2X & stopped the ceiling 2X5/8 layer at the wall drywall. Any ideas of how to fix the top of wall condition so it remains 1 hour rated? I was thinking that two layers of rated drywall attached to the top but what to do at the bracing? 1) remove & reinstall bracing? 2) foam fill rated foam around the 2X bracing?
  14. Good info, I changed the "End Cap" to 1/64 In CAD Detail with the "Show Line Weights" ON it looks good. With the Line weights off it looks like dots.
  15. Here it is in the layout with "Use layout Line Scale" with 1/64 line & 1/64 space. Not too bad but does not help in the actual work environment (CAD Detail)
  16. I know you can use the Layout DBX to change the line style look but that is not helping me working in CAD Details.
  17. Does not seem to help. Is there a scale factor applied to line styles other than layout
  18. I am doing details in a CAD Detail in the plan file. I want to draw in actual size. So when I draw a 12"x12" rectangle & want to add a hidden line (very small dashed line) the start & end segments are too large. Is there a line scale setting for that CAD detail workspace? If not I need a much smaller line definition, but can not create it. I must be missing some critical information. Any guidance would be appreciated. Thanks
  19. Thanks Robert, that will be the easy enough to implement. PS That did the trick.