Everything posted by DRAWZILLA
-
One way is to make your drawing a large on your screen ,as you can, before sending to the layout or printing. Another way is to ray-trace it b/c you can adjust the resolution there.
-
labels are causing a problem in elevation views
DRAWZILLA replied to DRAWZILLA's topic in General Q & A
Thanks,Scott It may be your apple system handles it different, for me I get at least a 30 second freeze and you know that is forever. I have sent all this into TS, lets see if they have any ideas. They should at least send it up the ladder now that others are experiencing the problem but please don't close the ticket until fixed. -
labels are causing a problem in elevation views
DRAWZILLA replied to DRAWZILLA's topic in General Q & A
Thanks Alan, I'll give it a shot but I really want it fixed soon. Thanks -
labels are causing a problem in elevation views
DRAWZILLA replied to DRAWZILLA's topic in General Q & A
Yes, Joe I really don't have any problems with camera views just section/ elevation views right now. Thanks -
labels are causing a problem in elevation views
DRAWZILLA replied to DRAWZILLA's topic in General Q & A
Yes, but I have one of the highest cards and still having problems -
labels are causing a problem in elevation views
DRAWZILLA replied to DRAWZILLA's topic in General Q & A
It seems that after I move a label in elevation view it hangs up, and I cannot select anything else unless I hit f12, then it refreshes. -
labels are causing a problem in elevation views
DRAWZILLA replied to DRAWZILLA's topic in General Q & A
No go, after further review, labels are still causing me a problem. -
labels are causing a problem in elevation views
DRAWZILLA replied to DRAWZILLA's topic in General Q & A
ok, found the problem, it was a setting in the NVidia control panel. I had it set for 16 and should be 4. thanks everyone Edit, didn't fix it. -
labels are causing a problem in elevation views
DRAWZILLA replied to DRAWZILLA's topic in General Q & A
Wow, I re-boot every day and shutdown every night. I thought it might be my mouse but I plugged in another one and, same thing. The only other thing might be in preferences b/c those don't transfer with the plan. Thanks for testing -
labels are causing a problem in elevation views
DRAWZILLA replied to DRAWZILLA's topic in General Q & A
Ok, here is the plan for your pleasure. Try a front elevation and select a few windows or doors if you can. labels are on. label problem plan.zip -
What's the difference between a floor joist and a beam?
DRAWZILLA replied to dshall's topic in General Q & A
A ceiling / roof beam will go on its own layer if you use those tools, I do all the time, love it and the won't get deleted when re-building the floor ceil joists. -
labels are causing a problem in elevation views
DRAWZILLA replied to DRAWZILLA's topic in General Q & A
Don't know why, sent the video and plan to TS. -
here it is
-
labels are causing a problem in elevation views
DRAWZILLA replied to DRAWZILLA's topic in General Q & A
All plans mostly b/c I use labels in my elevations -
labels are causing a problem in elevation views
DRAWZILLA replied to DRAWZILLA's topic in General Q & A
Ok, it might be a setting, but tech support can't find anything yet and they were also having this problem thanks, Tommy -
I have been running into a problem with labels in elevation view, a big slowdown in performance. here is the video http://screencast.com/t/yLypKp7tyEs Anyone else having this problem?
-
I have also seen this, not sure why.
-
I think the last time took longer b/c of the mac thing. I'll bet their on time this year, it will come out with the show in early feb.
-
Ok then he has some on chieftutor.com then. look in his section.
-
look at his YouTube channel. he did some new ones
-
Yes, I really don't do door or window sections as I'm not even sure what the contractor is putting in b/c the homeowner hasn't selected it yet, most of the time.
-
I agree, the best thing would be to block up the plate line to carry the roof load, I was just commenting on the way his 2nd drawing showed, not sure whitch one he wants.
-
Exactly, that's why I love them, and you get a laugh at the same time, why you ask, b/c we have all been there, and can relate to them
-
Yes, Richard, I would run the c.j. through to connect with the rafters or provide separate rafter ties. In most standard conditions 5-16d nails are usually ok unless you have something unusual going on there. I think his first post shows that.