rgardner

Members
  • Posts

    2922
  • Joined

  • Last visited

Everything posted by rgardner

  1. Or right click on an empty part of the toolbars and change the configuration there.
  2. I am sorry but you are using software from 6 years ago. I would venture to say since at least X10 and most likely before that due to my skill set improving with the use of the software that there has not been a regular basis need for editing plot lines. I have found without exception that 99.9% of the times those errant lines are on there is because the model is not accurate or built how chief is designed to work. It can be done. I do probably a good hundred plan sets a year from large full customs, additions, kitchen and bath design, etc. I cannot even remember last time I have had to use the edit plot lines tool.
  3. This is a contradictory statement. I have maybe one job in a year where I may need to cover an errant line or use the layout remove plot line tool. That is honestly being generous as I really can’t remember the last time.. accurate model will not have those lines.
  4. Open to below room outside of the invisible railing with the floor set to the depth you want the posts to go below the adjacent floor (12" lower in this example). You have to set your newel height to the different height as well.
  5. Railing tool alone, invisible, just posts, just glass all railings. 5 minutes so not exactly what he is looking for but it can be done.
  6. I disagree. I think three railings or two and an invisible wall would do this just fine…. Just need to set two of them as partition. One for the newells and one for the glass custom panel.
  7. Next time just add it to the cabinet and select 50% open and you can show open and closed and have the specs built in.
  8. Setup a Layer set for your 3d view that turns off the roof. Then you can change what level you are on as well. in X11 at least and it may even be available in X10 (I just cant remember) there is an OOB Layer set and camera view that will allow a "doll-house" view which you are describing. It is called the "perspective floor overview" camera.
  9. Locked layers? Reference display item? etc. If restarting and checking those two options probably best to post the plan file.
  10. If you are in the habit of creating a full backup of the plans in a dated folder and duplicating the folder (changing date only) for any revisions, then this issue would go away. The AB, New, layout files will all remain the same name and all the referenced files stay in the folder.
  11. All or none. Pretty sure you will need to model this you will need to select it as no soffits and then place ceiling planes for the enclosed soffits.
  12. Those are no longer rafters but roof beams in chiefs modeling world. They will be placed manually. The roof framing is the foam section of sips.
  13. This is totally doable but very separate in nature. Better to post this as a separate post. There is many ways to accomplish it and one would be a custom material instead of individual backsplashes. In this way you can set it so all grout lines line up in the X,Y axxis. Post it up and you will have lots of support.
  14. I have seen the menu bar disappear when having a 3d view up but have never been able to reproduce the issue so even though I reported it they don't have a way to find out the issue to fix it. Typically I can flip through my screens and select the different views I have open and eventually it will pop back up. Never the same thing and very sporadic maybe once every two weeks at most.
  15. Although there are some benefits to doing this I have had issues with several window companies adapting this to their window orders. Marvin and Pella being two of the ones that refused to have different numbers for identical windows. This honestly would be my preferred although in some of these bigger houses the window schedule gets really long... But I have had so much push back that I continue to keep the similar ones checked and when I need to differentiate I will either have a comment on that door (even using a macro for swing or hinge, etc.) so as to separate the minor differences.
  16. Find the schedule column that reports the difference or create a custom field set to slide direction and add that info to those two doors. It will number them separately. btw @GeneDavis I will be in Naples next weekend.
  17. rgardner

    Macros

    https://chieftalk.chiefarchitect.com/search/?q=year macro&updated_after=any&sortby=relevancy&search_and_or=and Third result
  18. I believe the OP has broken the wall and manually adjusted it.
  19. Most common methods would be using: Moldings Wall Caps But you can also use: 3d Solids Roof Planes Ceiling Planes Cabinets hmmm probably forgetting about 20-30 other methods that are more creative..
  20. It's nice that newell thanked you. I will go ahead and mark your answers with an upvote at least for your guys' effort!
  21. Make sure they are turned on in your layers. When you select them (you may need to either turn the fill off of your cad polyline) in the bar at the bottom of your screen it will show what layer and what group they belong to.
  22. My best guess after looking at the photo above is that it was some attic walls of something that was over there. Whether it was from a previous house that you had drawn there and deleted the main walls and then did save as method or something you drew over there and then moved or deleted. Probably your changes forced Chief to redo the attic walls and recognized there was nothing there to build auto attic walls for. But again just a guess based on the picture.
  23. @johnny Is a licensed architect out of Anacortes, WA who uses the software. @jbaehmer and myself are both Architectural designers who are based out of and do lots of work in Western Washington. I cannot speak to the others but I assume they are as busy as I am. I personally couldn't take on the job for probably 3-4 weeks at least.