I'm sure it's not the same, but I kept having crash problems on my 128GB iMac and it was directly related to that RAM. Scaled back to 64 and no problems since. In my case, the RAM was 4 mismatched 32's from OWC. Bought 2 new 32's and bingo. If all else fails, might be worth checking into. Even if just reseating the RAM.
-
Out of curiosity, does this happen on both of your Macs?
-
One way would be to select the walls you want, and create a materials list from the "selection". The "Siding" category should give the square footage, and it doesn't include windows or doors.
-
Manufacturer Catalogs>Clopay® Garage Doors>Modern Steel Collection>Modern Steel-Flush, Window.
-
With a reduced gable truss, you could still assemble on the ground and fly it right over the gable truss. Necessary in snow load country, if not in AL.
-
Using a pony wall might simplify creating the stone cap on top of the stone veneer.
-
Yes. But I forgot that "volume" was not yet an option in the room schedule in X12. My apologies. However, it is weird that your Interior Area (Sq Ft) is not calculating.
-
Thank you Steve. Very informative.
-
If you change to "interior dimensions" in your schedule, instead of "standard dimensions", it may help. I think the "volume" calculation uses interior numbers.
-
Showplace Wood Products® Library. Style "Pendleton II". Just use the door for the drawer.
-
Do you have the foundation set to rebuild?
-
Any plant packages have correct "Western Red Cedar"?
DG1949 replied to WhistlerBuilder's topic in General Q & A
Agreed. Very limited. Twinmotion? e-on Plant Catalog? -
Maybe a wall layer that is designated as "framing" that shouldn't be?
-
Any plant packages have correct "Western Red Cedar"?
DG1949 replied to WhistlerBuilder's topic in General Q & A
Thuja plicata? -
Interior/ Exterior Gable Wall Materials Won't Change
DG1949 replied to SBCWyoming's topic in General Q & A
Maybe select the wall and hit the "reverse layers" button on the edit bar. -
50? I can't remember that far back!
-
When I manually add a "furring wall" to the inside of the concrete stem wall and refresh the auto story pole dim, it adds 1-1/2" to the "top of Foundation" elevation. If I create a foundation wall that includes the furring wall from the start, it works correctly. Is yours manual, or part of your "foundation wall" type?
-
Plan with decks, material list only reporting deck boards, no framing
DG1949 replied to GeneDavis's topic in General Q & A
As soon as I re-built the framing, I got this: So it must be related to manual framing. Disconnects evidently. -
Plan with decks, material list only reporting deck boards, no framing
DG1949 replied to GeneDavis's topic in General Q & A
No, sorry, Gene. I also could not access your file. I just did what I did in one of my own. Do you get no "Decks-Walks" materials if you generate a list for all floors? -
Plan with decks, material list only reporting deck boards, no framing
DG1949 replied to GeneDavis's topic in General Q & A
If I try to get a material list by selecting the deck "room",, I get nada. If I calculate all floors it shows up under I.D.: Decks-Walks. But at least I can shut all else off and isolate the deck mats that way. -
You weren't using Universal Control when that was happening by any chance? I was freezing, crashing and burning until I realized CA doesn't like Universal Control (using same mouse and keyboard on two computers at the same time.)
-
Uncheck "Framing" on the Drywall layer.