GaryOhmer

Members
  • Posts

    195
  • Joined

  • Last visited

Everything posted by GaryOhmer

  1. Usually what's obvious is the first to overlook
  2. You might not have the window in full - grab the top of the chief window and snap to the top , should restore full window
  3. Everyone of those houses would already be in the mold and rot stage here in Ketchikan, Alaska - our record rainfall is over 16'
  4. I'm using an old mx master and have no problems at all
  5. I use the desktop version - does it work with x13?
  6. I do mostly interior trim any more - so when I draw a hall with a 36" door at the end I make the hall 3'11 not 48" - 2 king studs and a cripple will give 5 1/2" per side x 2 + 36 = 3'11 so I frame all my closets etc over by 11" , 5 1/2 each side
  7. I open the room - name it closet - the font size is 4, I want a size 3 - so after naming room I double click the name to change the font - I'd like to do that when I name the room.
  8. I'd love to change the size of the room font right when I name the room.
  9. You can always use a custom ceiling planes to do the job
  10. make as many of the walls that that you want invisible
  11. Is chief redoing the cabinet catalogues?
  12. I know that you can do the sides , but what about the top and bottom - matching two opposing roofs
  13. Is it possible to create a isosceles trapezoid window?
  14. THESE PLANS HAVE BEEN DRAWN FOR THE CUSTOMER AT THE CUSTOMER'S REQUEST. EXTRA ENGINEERING MAY BE REQUIRED FOR SPECIAL FOUNDATION DESIGNS DUE TO SLOPE & SOIL CONDITIONS AND A LATERAL ANALYSIS MAY BE REQUIRED FOR WIND AND EARTHQUAKE DESIGN. OHMER'S RENDERINGS MAKE NO WARRANTIES, EXPRESSED OR IMPLIED, REGARDING PLANS. CUSTOMER SHOULD HAVE PLANS REVIEWED BY A LICENSED BUILDER, ENGINEER OR ARCHITECT PRIOR TO CONSTRUCTION, SOME MODIFICATION MAY BE NECESSARY FOR COMPLIANCE WITH LOCAL AND STATE REGULATIONS. Is what I use on my plans
  15. Search for pool table instead of billiard table in library
  16. ANOTHER WAY IS TO USE 2 CABS - 1 WITH NO TOE KICK OR COUNTER TOP 4" TALL X 21" DEEP WITH DRAWER - 1 CABINET 32" TALL 4" TO FLOOR - SLIDE OVER 4" HIGH
  17. Don't have a problem here - looks like the counter top has the transparency set other than default
  18. Open the main wall dbx and go to structure and balloon thru ceiling above - then eliminate the attic wall
  19. If you go in and change your gable and eve fascia to 11.25 your ceiling line won't stick out
  20. From what I can see - your rafters are 9 1/4" but your fascia is only 7 1/4"