Room Names Eliminated in X-15 Why!!!!!!!!!!!!!!!!!!!!?
architect replied to Archnot-Boltz's topic in General Q & A
To further hijack the thread... How about away to automatically sequence room type names with numbers. i.e. Office 1, Office 2 Eric, X15 & a computer. -
I know...It is sad that I am looking this stuff up on a Saturday, but inquiring minds want to know. This is from an adjustable column manufacturers ICC-ES code evaluation Installation instructions: 4.1. The Marshall Extend-O-Column must be installed with the adjustable screw mechanism on the bottom. The entire adjustment mechanism, including the entire collar nut, shall be encased in minimum 3500 psi (24.1 MPa) concrete "Zip" Column report says you can "damage one thread 1-1/2" for 1/2 its depth" and must be installed with threads must be at the bottom. That makes it part of the code if you a going to use it. Eric
-
Ryan, Looks like I am a little weak on the "code required" part based only on : IRC R407.3 Structural Requirements: The columns shall be restrained to prevent lateral displacement at the bottom end. But manufacturer's instructions require the screw be welded or encased in concrete, so I guess that becomes a requirement. Eric
-
Codes require the adjustable part to be welded or cover the threads with concrete after installation. Down is the correct orientation with the threads below the slab. If you were jacking/leveling for a reno would be a different? Eric
-
DB,,,, Thank You. Problem solved. A Pile is essentially a telephone pole beaten into the ground or a metal screw used to hold up a building when you have crappy soils instead of using spread footings. Gene... I will try as a cabinet also.. but my Piles are round. Thank You, Eric.
-
Thank you in advance... I need to develop a Helical Pile plan and provide a unique label/number for each Pile to generate a log/schedule. Using x14 polylines in a schedule (or a symbol but 3d is not needed/wanted)..... How can I generate a different schedule number for each pile if the polyline or symbol is the same for each pile.? Using its x/y location would be great but does not seem to be an option?. Eric.. X14, WIN11/I7/16ram/RTX3080
-
Pdf size has been a big problem for me also on large jobs... I am using a program called Small PDF ($12/mo) that seems to do a good job of compressing the file. I also found that using 144dpi is fine for printing working drawings and I can not tell the difference on D size prints from 300dpi. (have not tried it for renderings) Small PDF also allows you to compress two files a day (so they say) on its web site for free (if you don't mind uploading/downloading to the web. Eric
-
Cross Section Call Out- Stop section display lines at building
architect replied to architect's topic in General Q & A
I think I will live with the no auto line /add manual line. Still a great time saver as it shows on all floors and references the layout page. Thank You, Eric -
Cross Section Call Out- Stop section display lines at building
architect replied to architect's topic in General Q & A
Thank you... the construction line are great except they seem to have the same problem...the line only seems to go all the way across on the double ended set up. x-13! Eric -
Copy dimensions floor to floor and remain attached to things?
architect replied to architect's topic in General Q & A
Thanks all for the moral support and next level tricks..... Also revisiting using auto dimensions ..... -
Have multiply floors that are identical. X13 I dimension one floor interior/exterior/windows etc. I can copy the dimensions to the next floor but they are "dumb" and not attached to walls/windows anymore. It works but leaves an x marks the spot marker ( can the points be turned off ?) and it would be better if dims were connected. Does a magic button exist to copy the dimensions and be attached to the same items on the next level?? Thank You in advance Eric
-
I would love to see that $12,000 system compared to a $2,000 system as far as "time it takes to" redraw, renders etc in CA.....
-
Maybe we are waiting on RTX 30xx graphic cards to actually be available to mere mortals...or Bitcoin to fall...again
-
Recently finished a 46 unit/mixed use apartment building that is 75mb + a 40mb "details" file. Things did not start to slow down till close to the end. I try to avoid images and PDFs added in Think it may just be a fact of life... Others using Revit for large projects have complained about slowdowns so It may not be just a CA thing. Eric CA 12 / i7 3.5ghz/ Geforce 1080 / SSD/ 16mb ram.
-
For me, Imported pdfs or images seem to make files really big for no reason and slow things down, Large numbers of windows, blocks or symbols also. I want one of those 9.66ghz chips with the built in fire extinguisher. Eric
-
Maybe a Microsoft Surface instead of using pad ?..... Eric
-
Tried 43" 4K and multi monitor set ups in the past....to much moving of mouse/eyes/head, etc. for my liking I find my self more comfortable/productive with one 30" 2560 x1600 screen. Although the monitor type is more expensive my 30" Dell has been working non stop for 18 years Eric
-
I am wondering....if you are scanning a house or office does it include every thing that is in the room in the scan (such as a dresser or the homeowners cat) How would these "point cloud" items get separated from the actual building.? Seems like you would need an empty building to get a useable As-built. Thanks, Eric
- 39 replies
-
- point cloud
- pointcloud
-
(and 8 more)
Tagged with:
-
Thanks for the feed back on my off topic q. .... Maybe just a pair of miners lights on my head and I am done. Actually I never installed the exhaust outlet to exterior in a windowless 1/2 bath and solatube makes a skylight/vent combo. They also can install and electrical light.... Thanks
-
Sorry to off topic a little... but has anyone had any real world experience with one of these tube skylights.? I would like to put one in my home but have never seen one out in the wild. Thanks, Eric
-
Maybe we would feel better if we talk to Revit/Archicad users and see what their delay deal is... We may not be alone on this when working on complex projects.? Eric
-
Looks like all that is needed is a 10ghz single core machine (and a fire extinguisher)…… My guess is a similar type model tested on Revit/Archicad would have similar delay times, etc ?. Eric
-
Just completed a 74 unit project and now working on a 42 unit mixed use.... I think it works well if you are working solo and know the program a bit. It does slow down once you add all the individual unit details/symbols...hold off on adding this stuff as long as possible. I use a separate "detail" file that contains... well... details, notes, etc. to keep the main file size down (not sure it helps). We do need a way of having a typical unit "block" that can be utilized My guess is the other platforms like Revit slow down also when you have large models???? Maybe not. I do find the size of Chief PDFs Con Docs to be way to large compared to other peoples work. I have to use drop box to distribute. Eric
-
Sometimes if I know the size of the "paper" the PDF was saved as (say 24x26) I can set the same paper size to be viewable via edit-drawing set up. Then just resize the import PDF to match that "paper" size on screen....I always check it by drawing a line to measure a known dimension P.S.: Set the Chief drawing scale to the scale of the PDF Eric