ACADuser

Members
  • Posts

    2823
  • Joined

  • Last visited

Everything posted by ACADuser

  1. Here is the slabs added with 1/2" overhang. Not sure if that is the finished look yet. For form & pour it may be easier to flush up the slab, no overhang, just stucco. Although I like the look of the overhang.
  2. Oh, so it was the entry spanning the rooms above that cause the error. The CC edge has always been an issue on porches. I just add a p-Solid for the edge display. Haven't found a way around this. Thanks for your time
  3. Can anyone tell me why the balcony floor shows a concrete edge over the entry room & not the side rooms? 18 mb file https://www.dropbox.com/s/fk7li1etj0u1yxp/Lou-1.zip?dl=0
  4. Messing about with this line type creator & thought I would share & see if it worked for anyone else. The DOT may be a bit large but give it a try. Wire Mesh LT.calibz
  5. I usually draw the fine details in autocad but today I thought I'd try to in Chief. It appears the Chief can not manage extra small dashes in line types. Or maybe I've missed a Linetype scale setting some where.
  6. Is that the expected/normal behavior? Yes, I was using the "Locate Wall" button from the framing view & that got me close.
  7. Creating a Header schedule I select one row & click the "Find Object in Plan" which takes me to the wall frame view instead of the plan view. Do I have a setting off or is this normal?
  8. FYI When you rotate a 3D solid in plan view the transform replicate command works as expected to move the object BUT the arrow keys do not move as expected. They remain orientated to the original position as created. Tech support confirmed the bug, and may be fixed in a future update.
  9. You are correct Joe. This is my reply to tech support after they confirmed the issue. Yes please report this issue. Seems short-sighted to allow "Call Outs", "Markers" & "Notes" to access the Room name but a ROOM "Wall Elevation Camera" to not allow access to a room name.
  10. Thanks Joe, but wanted the camera to pick up the room name it was in & the layout to display that room name in it's label. Once you type in the rooms name you do only have to alter it in one place, the room dbx. Is there a prefix to %room.name% that would work in the camera NAME field?
  11. So a regular Call Out will pick up the Room name, see clip: But a Wall Elevation Camera will not pick up the room Name?
  12. Working on dinner so I'll pick this up later. What I was thinking is that the camera could pick up the room name from the room it was in. That could be used as the label of the layout created from that camera. This means only the room name need be changes to change the layout label name. later
  13. Is there a way to link the room name into the Wall Elevation Call Out ? So you can use it in the elevation layout box?
  14. All that and the solid as a column within a wall with windows & the leader will not find the column. Not worth the aggravation!
  15. I set my leaders to attach on the tail only so I don't have issues bumping the text around. The leader behaves & doesn't mess with the level line.
  16. I told you I was brain dead today. Thanks Michael!