Glenn: Now that you've found that, I know how it happened but it didn't dawn on me that there was actually a 2nd floor built. I had my customer here yesterday and we were doing a bunch of edits on the plan that he wanted. His builder was here as well and we got to talking about the floor system and how he preferred to use 9.5" I-joists. My default floor system is 11.875 joists. So I was going to "quickly" put a crawlspace foundation under the plan and accidentally clicked on the Build 2nd Floor tool. I should have did an undo but instead switched back to Build Foundation. I backed out of doing the foundation as I had to make some default edits to get the 9.5" deep floor to build - hence no foundation under the plan I sent. Thanks for finding that. I had just upgraded to the latest version of X16 and was seriously wondering if my problem was related to a bug in the update ... but being able to build the vaulted ceiling in the patio room seemed to indicate that there was something I did - something I was missing - hence my post here.
-
I will have to see if I can remedy that. Thanks Gene. I've been away from the forum for some time. Closing the plan seems to be the right direction to go. V4_Lauer_X16.zip
-
I am working on a project that calls for 2.5:12 vaulted ceiling planes over the great room/kitchen area and the same vaulted ceiling spec's apply to the covered patio room on the exterior. For some reason unknown to me, I cannot get the vaulted ceiling planes to show in the great room and kitchen area but I can get them to work for the patio. I am attaching the plan as is (no foundation yet). If someone can spot something I am missing or doing wrong, I would greatly appreciate knowing what I need to do to get the vaulted ceiling to work in the great room/kitchen area. Thanks. V4_Lauer_X16.zip
-
I "think" I agree with Gene.
-
If your shade is suppose to look like a lamp shade, use a 2nd cone with slightly smaller dimensions, combine them (same center axis) and then do a subtraction of the smaller diameter cone from your larger diameter flat topped cone.
-
Dermot: Thanks for the tip on breaking the stairs etc. I think it would be nice if that disconnect tool showed up next to the stairs edit tools in the edit tool bar. I don't think I've ever used that tool before. Nevertheless, that's a great way to edit a stairs.
-
I have found USGS maps on line with contours for the areas where some of my projects were located. Unfortunately, there are no elevations data bases the way I've used those maps. I just rescale them as best I can and then recreate the elevation contours using elevation lines and points. Keep in mind that unless you can get a 7.5 minute map, the contour intervals are large. If the area is not very steep, this method is more or less useless, especially if the property isn't very big.
-
Or maybe use the landing tool. Put it at whatever elevation it needs to be. Then you can use the Alt key to draw the stairs from the deck down to the landing and the same for the stairs from the landing either down to the ground or down to another landing etc.
-
You could even create a lampshade.
-
Doug: For stairs that need to be code compliant, I am still wondering why the min/max values you are suggesting couldn't be hard coded in the software. But, if other countries have different standards, then maybe that is not a good idea. I am reasonably happy with the way the tread depths and riser heights work at this time. I've got a hunch that there won't be too many users that will want to change this functionality of the stair tool ... but it never hurts to try. Maybe your ideas will lead to even something better as I think the stairs tools are regularly being looked at for improvements.
-
Mick: Your findings seem to mirror mine. Not a real big deal to change the number of treads once you place the stairs. Seems like they could fine tune the coding to allow you to spec the number of treads. I won't be losing any sleep over that aspect of the stairs tools though.
-
Doug: It works for me. Riser height is dependent on the number of treads. With the bullet in "Lock Tread Depth", if you input a different default tread depth, the value you input should hold once you close the dialog and then place a stairs in the plan. One thing I did notice is that when changing the tread depth value (with the bullet for Lock Tread Depth" still selected), if I also change the number of treads from 17 (seems to be a default setting - I am using a 109.125 ceiling height) to some other value, and then click in the plan to place a new stairs, the number of treads for the stairs changes to back to 17. I then have to manually change the number of treads to what I want. I guess I've never noticed this before and it seems like it might be something that should be changed but I think I'd want to play with it a little more to see why Chief makes it work that way. When I change the number of treads before closing the dialog, I can see whether or not the number of treads I have inputted makes the stairs out of compliance with the code mandated 7.75" maximum riser height. Seems to me like changing the number of treads as well should work as long as it is within code requirements.
-
The type of return you want to make is a "hip" return. Select your gable wall and under the roof tab, make your return settings hip and you should get close to what your are trying to duplicate.
-
Assumptions can get you in trouble sometimes. I have seen contractors in my area who don't do kickout flashing so you would "assume" that if you put it on the plans, that it would get built that way. I've put things on plans that do not get done that way, so you realistically you can't assume too much. As they say ... "the devil is in the details" ... !