Posts
2247 -
Joined
-
Last visited
Content Type
Profiles
Forums
Gallery
Everything posted by Gawdzira
-
Is there a setting to avoid the overwhelming size of temporary dimension arrows as I zoom into a selected object?
-
Issues sending layout pdf to a print shop (Staples.com)
Gawdzira replied to MCCCcc's topic in General Q & A
https://theplanprinter.com/blueprint-printing-online-arch-d-24-x-36-blueprint-architectural-construction-blueprints-printing-service.html -
The type of image you are showing in the model is going to be custom painting on your elevations. You will not get that in a Chief model due to the lack of texture repetition. If I was doing this I would do something close and then run the rendered image through https://fotosketcher.com/ and make it super dirty so it is an idea of the texture. For the actual elevations I would hand sketch over the mostly blank elevations (texture very vague).
-
First printing to PDF and then printing that PDF is the most reliable path.
- 1 reply
-
- 1
-
Basic slab door with upper window?
Gawdzira replied to Christina_Girerd's topic in Symbols and Content
Jim's in the box thinking. -
Thanks. I may have drawn that one slightly out of the orthogonal plane?
-
I am not sure what I am doing so wrong? Adding custom rafter tails and I am not getting my rafter to build correctly. What am I doing wrong? Tail line that I exported to the library. 3x4 rafters I am only working on the garage/adu building on the left side of the plan. I saved that elevation camera with the line drawing of the rafter tail Thanks for any input. Roof actual YAN ADU V1 export.zip rafter tail a.calibz
-
select your walls and check this button
-
Before adjusting the wall on the left that that is 2'-10 15/16" after adjusting the wall by clicking on the dimension string and changing 2' 10 15/16 to 3'-0, I lose the dimension segment at the 3' section. I have not seen this before but I generally don't dimension to centerlines of walls. It still does not seem like something positive for that dimension segment to vaporize. YAN as built v1.zip
-
It sounds like the best approach would be to make the room ceiling ht. 14' in order for that to be the plate height where the rafters/trusses bear. Then place a dropped ceiling at 9 or 10'. In the roof tools there is a "Ceiling Plane" tool. Place a ceiling plane and adjust accordingly.
-
Roof Ventilation Details - Cali WUI
Gawdzira replied to flightcrazed's topic in Building Codes and Compliance
Good to know. I wonder if you could do that with Zip R on the roof sheathing layer. I will quiz my engineer about that. That would be a lot cheaper than spray foam and less likely to poison the workers. I can smell that spray foam for days and I always suspect if you can smell it, it is not your friend. -
Roof Ventilation Details - Cali WUI
Gawdzira replied to flightcrazed's topic in Building Codes and Compliance
I think the r-5 is short on the ratio you would want for the flash and batt or "perfect roof" system. I think you want closer to 25% of your insulation value on the top side or the spray foam layer to cut off the dew point issue. Are you looking at the info from Building Science Corporation? I assume you are since you mentioned "perfect roof". https://buildingscience.com/documents/reports/rr-9904-unvented-cathedralized-attics-where-we-ve-been-and-where-we-re-going/view -
help What is this little slice in my wall?
Gawdzira replied to ChiefUserAndrew8's topic in General Q & A
What is the ceiling height of the room? That is likely the top plate. By uploading the .plan file this would be easier to ascertain. You must close the program before zipping the file. Also, if you build framing for the walls and roof it may reveal more to you. -
Roof Ventilation Details - Cali WUI
Gawdzira replied to flightcrazed's topic in Building Codes and Compliance
All of the unvented assemblies I have done so far have been Flash and Batt. I am in climate zone 3 so about 2.5" of spray foam (approx. r-19) and then batt to make up the difference to get to r-30. The spray foam goes in before the sprinkler piping to avoid a hot spray foam to piping issue. For my next project I am looking towards something like you show #2. #4 looks expensive for construction and still gets you the fire issue for embers entering the assembly. With #2, either fill that soffit with spray foam or vent it. That is an area where you will have issues if it is left as shown. -
Roof Ventilation Details - Cali WUI
Gawdzira replied to flightcrazed's topic in Building Codes and Compliance
The other question is, why are you doing a vented roof assembly? There are good options for unvented assemblies even if you want to avoid spray foam at the underside of the sheathing. Depending on the size of your roof, with Vulcan vents running continuously on each side that is a lot of money. The last time I purchased Vulcan vents (a little over 2 years ago) they were over $10/ lin.ft for the eave/strip vent type. For fire issue reasons, I have been avoiding vented roof systems as well as vented crawl spaces. -
Roof Ventilation Details - Cali WUI
Gawdzira replied to flightcrazed's topic in Building Codes and Compliance
From that diagram, is the Vulcan vent only at that location. Do you have eave venting? In what I have built I put the Vulcan vent at the point of intake (eave in my situation). This does not make sense to me to have the Vulcan vent at this location. In theory, the top of the roof would be an exhaust as the heat would rise and exit there. But, in the event of a fire, would this still be the case? Therefore, I would supplement the Cor-A-Vent with 1/8" HDG screen mesh. -
I realize why ChiefTalk does not have a monthly contest on most creative screen names because Astrigal has sealed it up.
-
What Glenn said (plus 1000 wds)
-
In plan view, just grab the desired corner and move it.
-
x14 Crashing when changing materials on any object
Gawdzira replied to rcmcdougle's topic in General Q & A
In the future I will strive to make my jokes funnier so as to better distinguish them from my often useless advice. -
x14 Crashing when changing materials on any object
Gawdzira replied to rcmcdougle's topic in General Q & A
This is the "switch" I was referring to. I am not on my machine with the GeForce to show it exactly but similar to the article. https://www.mlc-cad.com/solidworks-help-center/how-to-force-solidworks-to-use-your-graphics-card/ -
x14 Crashing when changing materials on any object
Gawdzira replied to rcmcdougle's topic in General Q & A
I can't point you directly to it but there is a switch on your video card where you establish priority settings for Chief Architect (or any other particular program). Find that and it may solve it. -
It is generally a lot easier in the long run to rotate the plat out of North and keep the plan on the orthogonal directions. Off angle plans are a world of pain.