  1. @HomeDesign724 how is the cross section working? you could have two pitches in the same cross section. there is only one pitch in the dialog box
  2. I think I understand the details, but how is the cross section working. you could have two pitches in the same cross section
  3. My guess as well for the details, but what about for the cross section he has? And if his two roofs on the section had different pitches? how would that work? @HomeDesign724 any idea how the cross section works?
  4. this may be a possible reason. CA is changing it under certain conditions
  5. what is dynamic in that cross section? I'm still not understanding what that represents. Is that actually the cross section of the house, and then further adjusted by that dialog box? What would a sunken living room floor look like and how would the one floor height change in the dialog box impact it? i.e. that dialog only has one floor height, what happens to a sunken living room when you change that height? Are all the annotations just put where they are with no user interaction? Impressive if it does
  6. do those details dynamically change size or remove components? For instance, if you specify 2x4 walls or 2x6 walls, does the one detail show a wider stud, or are there two different details? and how does the cross section work. The entry screen shows 8'1 floor heights, but the image show 7'9? The dialog shows 12:12 roof pitch but the cross sections shows 6:12. does the roof pitch CAD line dynamically change pitch? what if the cross section had a sunken room? Are all of those arrows dynamic, in which if you made the basement 10', they would all move up/down with the change in height? For me I have details similar to yours, cathedral, and normal. I then have variables in each where you specify the R value, cladding type, sheathing type, floor size, etc, but the CAD lines are static, only the text changes Watch Rene's video above, he has pointers which is similar to your radio buttons
  7. I would disagree this is the same, CA permitted for years, there was not a no transfer rule. it was their discretion. this makes it defacto policy, not against a rule, because there was no rule prohibiting it
  8. analogies are like statistics I can always find one that goes my way. I will agree with Lew on this one. If a company for years permits transfers, that is a defacto policy by CA, and now they are changing it. Contractually they always had the right to not allow it, but in their own internal policies I would find it hard to believe they did not have a policy/email/directive/internal memo etc which permitted it here's another analogy, for years you left your house, drove down the street and drove around the City. Then one day the city decides to close off your street and your car can never leave the street. and if you do not think this happend, there was a guy in coloardo? something similar happened to his shop. I think he then went postal with a self made armoured vehicle. Or the electric company can go put poles on their right of way on your property, or the gas guy can .... sorry, I'm never a fan of analogies, unless it is an analogy of a company or person's own behaviour/actions
  9. F01 is much better. I will log a ticket as the default should be working you would think they would have a profiled jamb to stop the door when it shuts f01:
  10. There is light coming through the jamb at left and at top Roof is there. backdrop intensity is 250. I lowered the exposure to 0.3 if i change the door is goes away setting is "sun follows camera" any ideas on how to fix? thanks
  11. For the garage, I tried reversing the wall, no difference when the stairwell is set to open to below, it is altering the basement wall. Not that that helps. but it is a clue to the behaviour. If that stairwell is set to garage, you get no foundation walls for the stairwell but the house foundation wall is then correct. Of course that would only introduce other problems so I am not suggesting doing that. If I set the laundry room to open to below, it does not shift that wall..so my guess is something about being in the garage The only way I found to fix is to turn off the auto build foundation and then move the basement wall to align, similar to Ryan's suggestion @rgardner I believe your fix for the other stairwell will also turn off the auto build The OP wanted to keep auto build on ...not sure that is possible
  12. I call floor plans and elevations "floor plans and elevations" and call renderings (3d) "renderings" or "3D renderings". CA's 3D model is just the means to produce those plans and renderings I use the phrase "Regulatory compliant plans" to note that I will stand by my services until they pass the jurisdiction's regulatory approval. ... just a tidbit on how to sell more
  13. I run 512 just fine. I know a lot of people say to get more, but not sure why. My understanding is you would have to check read/write speeds and then decide. But even that I'm not sure would make much of a difference with CA, as I assume CA caches to memory for the vast majority of functions (and I would assume you have enough memory that the disk cache is not needed). So the question would be how often does CA read and write to disk, and is it enough to make a difference. (queue the multitude of comments to come from people who have actually measured as I am purely speculating ...) My windows and installed programs are about 130GB this leaves > 300GB. With my CA directory for each client being mostly topping out at 300MB, I could do 1000 projects before I run out of space .well i just did some playing around and CA is reading and writing to disk fairly frequently, so probably best to check the performance of each size of drive. so maybe buy more for performance if it is significant and cheap, but for pure storage, 512 GB is lots, at least for me. I also have a backup drive, so storage is even less of an issue it does bring up a question, what exactly is the best bang for one's buck for performance, CPU, video card, video card memory, etc.
  14. looks like the key here is to ensure it is flat on the x,y plane . this works: 26.11.2022_16.57.59_REC.mp4
  15. I am looking for a CAD block for a heating element in a duct for a makeup air unit. I found a nice symbol, wall radiator towel warmer. but its 2d block is a top view. is there a method to convert the symbol's other plane into a 2D CAD block. i.e. I want the picture below as a CAD block thanks
  16. curious, how would the client even know. It is fairly typical around here to have storey pole elevations in Metres above sea level, but that can be accomplished even if one does 2. ..maybe there is a downvote bot...as I cannot possibly see a reason to downvote your assessment
  17. i would try: 0. leaving main floor at 0 1. entering all the terrain points 2. determine the distance from the subfloor to the terain at a specific point adjacent to the house 3. adjust the "subfloor height above terrain" to match so for instance if the terrain is at 97' ASL at the front of the house and 95' ASL at the back of the house and you want the subfloor to be 3' above the front of the house, the value would be 100' Below are two terrain regions left at 97', right at 95', and "subfloor height above terrain" at 100' but i've never found a way to autostorey pole it correctly. if you set the grade level marker in the defaults to -100 ft and then remove it from the storey pole dimension, it will show correctly... just requires the manual work, but maybe others have found a way.
  18. I thought about this as well, but then decided maybe upgrading the hardware more frequently would be the better choice, as you never know what might be coming next, plus you get the new o/s when you upgrade HW
  19. I believe you could implicitly figure out level 3 is the attic by using a room label macro, and then publish that to a global variable. But as the OP desires this on layout, the plan would have to be open as well to run the room label macro (or start reading and writing files). Me thinks it would be a lot of work ensuring the value was for the specific plan
  20. one thing I have noticed is my memory is not pinned, video card memory is not pinned, and my CPU is not pinned but CA is not "lightning quick" . so I'm not sure the extras you are scoping out would be much better than half of what you spec. ...but that is just my experience. I'd be curious to find out what exactly if anything is a measurable difference, because then I think everyone could spend the money on what is making the difference. i.e I'd go spend the extra $500 on the better processor if that was the factor
  21. i do a fair amount of basement entries, just not usually fully enclosed (usually post and roof, or just railing). But there are a couple things to ensure you do in order to avoid redoing. 1. set the terrain height correctly relative to the main floor of the main building. I typically measure this with a tape measure against a known entity, such as front steps or window (then you go inside an ,measure distance to floor) 2. Once that is set, measure your top of concrete stairwell walls from grade. Usually here it is above grade a few inches.your picture looks like ~8 inches 3. then adjust your exterior room height at the basement level you created to have the proper ceiling height to match 2 4. pull a section and make sure the measurements are correct then do the rest