MichaelJerome

Members
  • Posts

    39
  • Joined

  • Last visited

Reputation

0 Neutral

About MichaelJerome

  • Birthday 08/10/1967

Profile Information

  • Gender
    Male
  • Location
    Meridian, ID

Recent Profile Visitors

941 profile views
  1. Thanks Ryan - Nice and easy - How does that get unchecked without me physically doing that?
  2. Can someone look at the exterior wall on the second floor high side and see why it is not rebuilding to meeting the trusses leaving a gap in the wall? Thanks, Michael Megale Center Plan 2.7.20.zip
  3. Is there a reason the window does not show up after I rebuild the framing as you mentioned? I can see it in the camera view but it does not appear or frame in the windows in framing wall detail. Any thoughts?
  4. Sorry - I missed that option - I thought it was only for the ceiling trusses. Thanks for your help!
  5. Okay - Do you know of a simple way to rebuild the floor trusses without changing the size individually?
  6. Thank you - Is there any reason why the reset to defaults does not update all floors instead of doing this manually room by room? I thought that was supposed to remedy these issues.
  7. I have updated my defaults to allow for a 14" floor truss between the two floors. All the dimensions show in the default setting DBX accurately but when they are commanded to reset to defaults the first floor adds 2" to the ceiling height but does not create the 14" space for the floor trusses. Let me know if someone sees something I missed. Thanks, Megale Center Plan 2.7.20.zip
  8. When I copied and pasted from one framing layer to the other it showed up on the small window side in the elevation view for whatever reason.
  9. Real close! There were wall divisions for the raised foundation wall for the planter but I may be able to do that and add the windows back hopefully and then add and adjust the headers. The image is what the smaller window and lower window would look like sitting higher on the stem wall below.
  10. Hi Robert, I am so close on this and communicating with the engineer for the details. I know you could probably complete it without issue but I am trying to learn the correct way of doing the processes I am questioning so I can provide the drawings myself without hiring it out. I already have a complete layout but the engineers requirements are not easy to implement with the restrictions I find in CA. Thanks, Michael
  11. Is this a problem, or something that someone looking at the plan should not suggest? Is "framing layer 4" a layer in Display Options? I am trying to display this wall as one layer. When I select the wall on the 1st floor and open the layer I see one and the other is on the second floor. If I am going to show this as detail for the framer I can't create it accurately without the wall sections being one not 2. Problem with doing this? No, problem with doing this as I am working on this right now but wanted to explain that the windows will not be able to be moved up or down due to the limitations of the headers and the closet roof. Are you saying you are unable to, or do not want to? The same layer as? I wanted to show you and others the framing that is to be drawn but I cannot get the framing layers to combine. #4 and #2 need to be one framing layer to display as a detail drawing for the framer and for plan review from the city to show the shear support as the engineer drew.
  12. Hi Again, After sending this plan to my engineer he has requested several things that are list in the pdf files. I can not combine framing layer 4 and 2 that are basically the same wall but separated. With the headers that the engineer is suggesting I will have to raise the ceiling, roof and trusses. I also need to have a soffit retained over the entry for lighting but have the outside ends match with no boxed soffit. The are layers in the wall that appear as shapes in the drywall that I cannot seem to find or eliminate. The windows cannot be lowered since the closet ceiling and the closet roof limit the movement in the wall. I have drawn red lines for the framing that the engineer has requested but can't place the framing on the same layer. I would appreciate any insight on how to accomplish this so I can get it back to him for review and have accurate details for the layout and city plan review. Thank you, Michael Megale Center Plan 2.7.20.zip 2nd Wall Layer 4 Megale Center Plan 2.7.20.pdf Megale Center Plan 2 2.7.20.pdf Megale Center Plan 2.7.20.pdf Wall Layer 2 Megale Center Plan 2.7.20.pdf Wall Layer 4 Megale Center Plan 2.7.20.pdf
  13. Once again Eric - Your insight is amazing and the video is sooo extremely helpful to follow along and correct the issues. I have not had any classes yet but follow Dan Baumann and watch some of his lessons. I am self taught like most and appreciate your knowledge to help resolve things as they come up and I can't find the exact resource to view like this. Many Thanks, Michael
  14. I have seen that but I felt there was a reason it was reverting due to an error that I had not seen yet.