I am Greatly disappointed in this! I have been a user since 1997 (Chief 97) I upgraded from every other year to every few years. I was doing fine with Chief V9.54 but when I had to leave Windows XP and go to Windows 10 Chief V9.54 wouldn't work so that forced me to X11 (Which I will say has been a mostly nice upgrade). But very costly upgrade. I am a general contractor and draw my projects from small project shop drawings to permitted house plans with as many as 6 or 7 pages. I just need to create permittable drawings, and give the customer some basic 3D views of what the project will look like, I'm not trying to win any art shows. Now I am going to be forced to pay $600 a year and achieve no greater benefit! Will be even worse when the economy tanks and there's nothing to draw and still have to pay out that $600 a year! It seems similar to some of these companies that turnout products that won't last half as long as they used to so you have to buy a new one. What happened to the days when you could buy something and it last a long time. Now they try to keep you on the hook so they keep getting money from you! To heck with this subscription crap!
-
Sorry for the late response, I have the forum set to notify by email when a post is made but never got the notification. Thank you both for your time. That worked perfect Levis.
-
Showing filled CMU downpours/rebar on floor and foundation plan
Statewide replied to PMMully's topic in General Q & A
I draw a 2" circle fill it solid and put it on the default cad layer, because I want it to show up on all pages. (the only thing I put on default cad layer is cad I will not turn off) Since most of my jobs are ICF I put dimensions for dowel locations and put them on the "Dimensions, Foundation" layer, since I don't want the dimensions to show up on any other page. I take an extra step and instead of a dimension line I use text to locate the dowel from a corner (kinda like a running dimension) that way the guy in the field can pull his tape and mark ea dimension without having to do any calculating. -
I thought I stumbled on it once but was unable to get back. I tried a search here with no luck. The closest thing I found was the octagon arch or dog ear arch but I need the two sides to match the slope with no flat top, as pictured. Thanks, Jim
-
Thank you, (maybe a 5yr old thread but helped me a lot today) I was having the same issue, placing dowels in the wall. I went from v9.54 to X11. Lot of nice new stuff, but miss a lot of old stuff. Now hopefully I will remember later that it's locked and not wonder why I can't move my walls. LOL
-
Can you explain how this is done please.
-
It is just a quick check to make sure the font and or detail is readable at that size, when at scale. No scratching the monitor it's just a small flexible ruler.
-
Is there a tool that will allow you to click and display the page you are on at scale? I usually just take a ruler and zoom in or out till it is at scale, to confirm that I will like it when it gets printed. Thanks, Jim
-
I totally understand that, but I have no desire to do something manually if it will do it automagically. Because if something changes than I got to go back and fix that. This program is way beyond my capability to use it, so I didn't know if there was a preset that I had not accessed to attain my goal.
-
And it may well be that way. I was just hoping someone knew if I was missing something.
-
Not when the pitches are different. I don't know how to simplify my first post any more than it already is. Yes that is how the fascia should look. but you raised the floor/wall height to achieve that and it appears the pitches are the same. If wall heights are the same, o.h. is the same, heel heights normal, pitches are different the fascia can not be level. This is what I want with autobuild roofs.
-
The fascia to be different heights.
-
Ya but I would've still had to give description of my issue. I have the "same height eaves" unchecked. And if I uncheck the "same roof height at ext wall" it still makes the fascia the same height, although it does keep the same amount of o.h. which is better but still not what I need.
-
Overhang at inside corner, 2 different pitches, main pitch 6", other pitch 3" , same wall heights. Automatic roof build. It is expected that the fascia elevations are different, the wall heights have to stay the same and o.h. stays the same. Program keeps making the fascia elevations the same by extending the overhang of the 3" pitch out, regardless of what the o.h. setting. Yes I can manually pull the roofs back but I prefer to utilize the automatic build as much as possible so I don't have to keep fixing something if a change is made. Thanks, Jim